On the use of polychromatic cameras for high spatial resolution spectral dose measurements

Author:

Cloutier EORCID,Beaulieu LORCID,Archambault LORCID

Abstract

Abstract Objective. Despite the demonstrated benefits of hyperspectral formalism for stem effect corrections in the context of fiber dose measurements, this approach has not been yet translated into volumetric measurements where cameras are typically used for their distinguishing spatial resolution. This work investigates demosaicing algorithms for polychromatic cameras based spectral imaging. Approach. The scintillation and Cherenkov signals produced in a radioluminescent phantom are imaged by a polychromatic camera and isolated using the spectral formalism. To do so, five demosaicing algorithms are investigated from calibration to measurements: a clustering method and four interpolation algorithms. The resulting accuracy of scintillation and Cherenkov images is evaluated with measurements of the differences (mean ± standard deviation) between the obtained and expected signals from profiles drawn across a scintillation spot. Signal-to-noise ratio and signal-to-background ratio are further measured and compared in the resulting scintillation images. Finally, the resulting differences on the scintillation signal from a 0.2 × 0.2 cm2 region-of-interest (ROI) were reported. Main results. Clustering, OpenCV, bilinear, Malvar and Menon demosaicing algorithms respectively yielded differences of 3 ± 5%, 1 ± 3%, 1 ± 3%, 1 ± 2% and 2 ± 4% in the resulting scintillation images. For the Cherenkov images, all algorithms provided differences below 1%. All methods enabled measurements over the detectability (SBR > 2) and sensitivity (SNR > 5) thresholds with the bilinear algorithm providing the best SNR value. Clustering, OpenCV, bilinear, Malvar and Menon demosaicing algorithms respectively provided differences on the ROI analysis of 7 ± 5%, 3 ± 2%, 3 ± 2%, 4 ± 2%, 7 ± 3%. Significance. Radioluminescent signals can accurately be isolated using a single polychromatic camera. Moreover, demosaicing using a bilinear kernel provided the best results and enabled Cherenkov signal subtraction while preserving the full spatial resolution of the camera.

Funder

Fonds de Recherche du Québec - Nature et Technologies

Natural Sciences and Engineering Research Council of Canada

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3