Mutual interferences between SIAT aPET insert and a 3 T uMR 790 MRI scanner

Author:

Sang ZiruORCID,Kuang ZhonghuaORCID,Wang Xiaohui,Ren Ning,Wu San,Niu MingORCID,Cong Longhan,Liu Zheng,Hu ZhanliORCID,Sun Tao,Liang DongORCID,Liu Xin,Zheng Hairong,Li Ye,Yang Yongfeng

Abstract

Abstract Objective. Dual-modality small animal PET/MR imaging provides temporally correlated information on two biochemical processes of a living object. An magnetic resonance imaging (MRI)-compatible small animal PET insert named Shenzhen Institutes of Advanced Technology (SIAT) aPET was developed by using dual-ended readout depth encoding detectors to simultaneously achieve a uniform high spatial resolution and high sensitivity at the SIAT. In this work, the mutual interferences between SIAT aPET and the 3 T uMR 790 MRI scanner of United Imaging was quantitatively evaluated. Approach. To minimize the mutual interferences, only the PET detectors and the readout electronics were placed inside the MRI scanner, the major signal processing electronic was placed in the corner of the MRI room and the auxiliary unit was placed in the MRI technical room. A dedicated mouse radio fRequency (RF) coil with a transmitter and receiver was developed for the PET insert. The effects of PET scanner on the B 0 and B 1 field of the MRI scanner and the quality of the MRI images were measured. The effects of MRI imaging on the performance of both the PET detectors and scanner were also measured. Main results. The electronic and mechanical components of the PET insert affected the homogeneity of the B 0 field. The PET insert had no effect on the homogeneity of B 1 produced by the dedicated mouse coil but slightly reduced the strength of B 1. The mean and standard deviation of the RF noise map were increased by 2.2% and 11.6%, respectively, while the PET insert was placed in the MRI scanner and powered on. Eddy current was produced while the PET insert was placed in the MRI scanner, and it was further increased while the PET insert was powered on. Despite the above-mentioned interferences from the PET insert, the MR images of a uniform cylindrical water phantom showed that the changes in the signal-to-noise ratio (SNR) and homogeneity as the PET insert was placed in the MRI scanner were acceptable regardless of whether the PET insert was powered off or powered on. The maximum reduction of SNR was less than 11%, and the maximum reduction of homogeneity was less than 2.5% while the PET insert was placed inside the MRI scanner and powered on for five commonly used MRI sequences. MRI using gradient echo (GRE), spin echo (SE) and fast spin echo (FSE) sequences had negligible effects on the flood histograms and energy resolution of the PET detectors, as well as the spatial resolution and sensitivity of the PET scanner. Significance. The mutual interference between the SIAT aPET and the 3 T uMR 790 MRI scanner are acceptable. Simultaneous PET/MRI imaging of small animals can be performed with the two scanners.

Funder

Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province

Scientific Instrument Innovation Team of the Chinese Academy of Sciences

National Natural Science Foundation of China

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference71 articles.

1. Geometry optimization of electrically floating PET inserts for improved RF penetration for a 3T MRI system;Akram;Med. Phys.,2018

2. Elimination of eddy current artifacts in diffusion-weighted echo-planar images: the use of bipolar gradients;Alexander;Magn. Reson. Med.,1997

3. MRI of tumor angiogenesis;Barrett;J. Magn. Reson. Imaging,2007

4. Isochronous assessment of cardiac metabolism and function in mice using hybrid PET/MRI;Buscher;J. Nucl. Med.,2010

5. Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner;Catana;J. Nucl. Med.,2006

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3