Author:
Mínguez Gabiña Pablo,Roeske John C,Mínguez Ricardo,Rodeño Emilia,Gómez de Iturriaga Alfonso
Abstract
Abstract
We performed Monte Carlo simulations in order to determine, by means of microdosimetry calculations, tumour control probability (TCP) curves for treatments with 225Ac-PSMA of metastatic castration resistant prostate cancer (mCRPC). Realistic values of cell radiosensitivity, nucleus size and lesion size were used for calculations. As the cell radiosensitivity decreased, the nucleus size decreased and the lesion size increased, the absorbed dose to reach a given TCP increased. The widest variations occurred with regard to the cell radiosensitivity. For the Monte Carlo simulations, in order to address a non-uniform PSMA expression, different 225Ac-PSMA distributions were considered. The effect of these different PSMA distributions resulted in small variations in the TCP curves (maximum variation of 5%). Absorbed doses to reach a TCP of 0.9 for a uniform 225Ac-PSMA distribution, considering a relative biological effectiveness (RBE) of 5, ranged between 35.0 Gy and 116.5 Gy. The lesion absorbed doses per administered activity reported in a study on treatments with 225Ac-PSMA of mCRPC ranged between 1.3 Gy MBq−1 and 9.8 Gy MBq−1 for a RBE = 5. For a 70 kg-patient to whom 100 kBq kg−1 of 225Ac-PSMA are administered, the range of lesion absorbed doses would be between 9.1 Gy and 68.6 Gy. Thus, for a single cycle of 100 kBq kg−1, a number of lesions would not receive an absorbed dose high enough to reach a TCP of 0.9.
Subject
Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献