Activity recovery for differently shaped objects in quantitative SPECT

Author:

Mínguez Gabiña PabloORCID,Monserrat Fuertes Teresa,Jauregui InésORCID,del Amo Cristina,Rodeño Ortiz de Zarate Emilia,Gustafsson JohanORCID

Abstract

Abstract Objective. The aim was to theoretically and experimentally investigate recovery in SPECT images with objects of different shapes. Furthermore, the accuracy of volume estimation by thresholding was studied for those shapes. Approach. Nine spheres, nine oblate spheroids, and nine prolate spheroids phantom inserts were used, of which the six smaller spheres were part of the NEMA IEC body phantom and the rest of the inserts were 3D-printed. The inserts were filled with 99mTc and 177Lu. When filled with 99mTc, SPECT images were acquired in a Siemens Symbia Intevo Bold gamma camera and when filled with 177Lu in a General Electric NM/CT 870 DR gamma camera. The signal rate per activity (SRPA) was determined for all inserts and represented as a function of the volume-to-surface ratio and of the volume-equivalent radius using VOIs defined according to the sphere dimensions and VOIs defined using thresholding. Experimental values were compared with theoretical curves obtained analytically (spheres) or numerically (spheroids), starting from the convolution of a source distribution with a point-spread function. Validation of the activity estimation strategy was performed using four 3D-printed ellipsoids. Lastly, the threshold values necessary to determine the volume of each insert were obtained. Main results. Results showed that SRPA values for the oblate spheroids diverted from the other inserts, when SRPA were represented as a function of the volume-equivalent radius. However, SRPA values for all inserts followed a similar behaviour when represented as a function of the volume-to-surface ratio. Results for ellipsoids were in agreement with those results. For the three types of inserts the volume could be accurately estimated using a threshold method for volumes larger than 25 ml. Significance. Determination of SRPA independently of lesion or organ shape should decrease uncertainties in estimated activities and thereby, in the long term, be beneficial to patient care.

Funder

Swedish Cancer Society

Mrs. Berta Kamprad’s foundation

Basque Government

Royal Physiographic Society of Lund

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3