Effective optimization strategy for large optimization volume object, remaining volume at risk (RVR): α-value selection and usage from generalized equivalent uniform dose (gEUD) curve deviation perspective

Author:

Anetai YusukeORCID,Takegawa HidekiORCID,Koike YuheiORCID,Nakamura Satoaki,Tanigawa Noboru

Abstract

Abstract Objective. A large optimization volume for intensity-modulated radiation therapy (IMRT), such as the remaining volume at risk (RVR), is traditionally unsuitable for dose-volume constraint control and requires planner-specific empirical considerations owing to the patient-specific shape. To enable less empirical optimization, the generalized equivalent uniform dose (gEUD) optimization is effective; however, the utilization of parameter a-values remains elusive. Our study clarifies the a-value characteristics for optimization and to enable effective a-value use. Approach. The gEUD can be obtained as a function of its a-value, which is the weighted generalized mean; its curve has a continuous, differentiable, and sigmoid shape, deforming in its optimization state with retained curve characteristics. Using differential geometry, the gEUD curve changes in optimization is considered a geodesic deviation intervened by the forces between deforming and retaining the curve. The curvature and gradient of the curve are radically related to optimization. The vertex point (a = a k ) was set and the a-value roles were classified into the following three parts of the curve with respect to the a-value: (i) high gradient and middle curvature, (ii) middle gradient and high curvature, and (iii) low gradient and low curvature. Then, a strategy for multiple a-values was then identified using RVR optimization. Main results. Eleven head and neck patients who underwent static seven-field IMRT were used to verify the a-value characteristics and curvature effect for optimization. The lower a-value (i) (a = 1–3) optimization was effective for the whole dose-volume range; in contrast, the effect of higher a-value (iii) (a = 12–20) optimization addressed strongly the high-dose range of the dose volume. The middle a-value (ii) (around a = a k ) showed intermediate but effective high-to-low dose reduction. These a-value characteristics were observed as superimpositions in the optimization. Thus, multiple gEUD-based optimization was significantly superior to the exponential constraints normally applied to the RVR that surrounds the PTV, normal tissue objective (NTO), resulting in up to 25.9% and 8.1% improvement in dose-volume indices D2% and V10Gy, respectively. Significance. This study revealed an appropriate a-value for gEUD optimization, leading to favorable dose-volume optimization for the RVR region using fixed multiple a-value conditions, despite the very large and patient-specific shape of the region.

Funder

Japan Society for the Promotion of Science

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3