Timing offset calibration for TOF PET using stationary line source scans at multiple positions

Author:

Li AngORCID,Zhang XuanORCID,Zhou Xiaoyun,Fang Lei,Hu Junpeng,Li BingxuanORCID,Zhang Bo,Xie Qingguo,Li Fei,Xiao PengORCID

Abstract

Abstract Background. Accurate timing offset calibration is crucial for time-of-flight (TOF) positron emission tomography (PET) to mitigate image artifacts and improve quantitative accuracy. However, existing methods are often time-consuming, complex, or costly. Objective. This paper presents a method for TOF PET timing offset calibration that eliminates the need for costly equipment, phantoms, short-half-life sources, and precise source positioning. Approach. We estimate channel timing offsets using stationary scans of a 68Ge line source, typically used for routine quality control, at a minimum of three non-coplanar positions, with each position scanned for two minutes. The line source positions are accurately determined by applying a simple algorithm to their reconstructed images, allowing precise calculation of arrival time differences. Channel timing offsets are estimated by solving a least squares problem. This method is assessed through analyses of phantoms and patient images using a RAYSOLUTION DigitMI 930 scanner. Main results. The estimated timing offsets ranged from –500 ps to 500 ps across all channels. Calibration with a minimum of three scanned positions was sufficient to correct these offsets, achieving less than a 1% discrepancy across various metrics of the image quality (IQ) phantom compared to 12 positions. This calibration significantly reduced edge artifacts in TOF reconstruction of both phantoms and patients. Furthermore, the IQ phantom displayed a 14% increase in average contrast recovery, a 61% reduction in average background variability across all spheres, and a 90% reduction in average residual error. Consistent with the phantom results, patient data revealed enhancements in maximum standardized uptake values (SUVmax) from 14% to 55% for lesions measuring 6 mm to 14 mm. The calibration also improved lesion-to-background contrast and eliminated artifacts caused by the spillover effect of the kidneys and bladder. Significance. The proposed method is fast, user-friendly, and cost-effective, effectively improving lesion detection and diagnostic accuracy.

Funder

National Research and Development Program for Major Research Instruments of Natural Science Foundation of China

National Natural Science Foundation of China

Sino-German Mobility Programme

Publisher

IOP Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3