Abstract Objective. Synthetic transmit aperture (STA) ultrasound imaging is well known for ideal focusing in the full field of view. However, it suffers from low signal-to-noise ratio (SNR) and low frame rate, because each transducer element must be activated individually. In our previous study, we encoded all the transducer elements with partial Hadamard matrix and reconstructed the complete STA dataset with compressed sensing (CS) algorithm (CS-STA). As all the elements are activated in each transmission and the number of transmissions is smaller than that of STA, this method can achieve higher SNR and higher frame rate. Its main drawback is the time-consuming CS reconstruction (∼hours). In this study, we propose to accelerate the complete STA dataset reconstruction with minimal l 2-norm least squares method. Approach. Partial Hadamard apodized plane wave (PW) transmissions were performed to acquire the PW dataset. Thereafter, the complete STA dataset can be reconstructed from the PW dataset with minimal l 2-norm least squares method. Due to the orthogonality of partial Hadamard matrix, the minimal l 2-norm least squares solution can be easily calculated. Main results. The proposed method is tested with simulation data and experimental phantom and in-vivo data. The results demonstrate that the proposed method achieves ∼5 × 103 times faster reconstruction speed than CS algorithm. The simulation results demonstrate that the proposed method is capable of achieving the same accuracy as the conventional CS-STA method for the STA dataset reconstruction. The simulations, phantom and in-vivo experiments show that the proposed method is capable of improving the generalized contrast-to-noise ratio (gCNR) and SNR with maintained spatial resolution and fewer transmissions, compared with STA. Significance. In conclusion, the improved image quality and reduced computational time of LS-STA pave the way for its real-time applications in the clinics.

Funder

Guangdong Key Project

CAS research Projects

Shenzhen Research Grant

Tsinghua University Spring Breeze Fund

National Natural Science Foundation of China

Beijing Natural Science Foundation

Youth Innovation Promotion Association of the Chinese Academy of Sciences

National Basic Research Program of China

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference42 articles.

1. A study of synthetic-aperture imaging with virtual source elements in B-mode ultrasound imaging systems;Bae;IEEE Trans. Ultrason. Ferroelectr. Freq. Control,2000

2. Spatiotemporal matrix image formation for programmable ultrasound scanners;Berthon;Phys. Med. Biol.,2018

3. Recovery of the complete data set from focused transmit beams;Bottenus;IEEE Trans. Ultrason. Ferroelectr. Freq. Control,2018

4. An introduction to synthetic-aperture radar;Brown;IEEE Spectr.,1969

5. Reliable estimation of virtual source position for SAFT imaging;Chang;IEEE Trans. Ultrason. Ferroelectr. Freq. Control,2013

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3