Monte Carlo study on dose distributions from total skin electron irradiation therapy (TSET)

Author:

Ding George XORCID,Osmundson Evan C,Shinohara Eric,Newman Neil B,Price Michael,Kirschner Austin NORCID

Abstract

Abstract Total skin electron therapy (TSET) has been used to treat mycosis fungoides since the 1950s. Practitioners of TSET rely on relatively crude, phantom-based point measurements for commissioning and treatment plan dosimetry. Using Monte Carlo simulation techniques, this study presents whole-body dosimetry for a patient receiving rotational, dual-field TSET. The Monte Carlo codes, BEAMnrc/DOSXYZnrc, were used to simulate 6 MeV electron beams to calculate skin dose from TSET. Simulations were validated with experimental measurements. The rotational dual-field technique uses extended source-to-surface distance with an acrylic beam degrader between the patient and incident beams. Simulations incorporated patient positioning: standing on a platform that rotates during radiation delivery. Resultant patient doses were analyzed as a function of skin depth-dose coverage and evaluated using dose-volume-histograms. Good agreement was obtained between simulations and measurements. For a cylinder with a 30 cm diameter, the depths that dose fell to 50% of the surface dose was 0.66 cm, 1.15 cm and 1.42 cm for thicknesses of 9 mm, 3 mm and without an acrylic scatter plate, respectively. The results are insensitive to cylinder diameter. Relatively uniform skin surface dose was obtained for skin in the torso area although large dose variations (>25%) were found in other areas resulting from partial beam shielding of the extremities. To achieve 95% mean dose to the first 5 mm of skin depth, the mean dose to skin depth of 5–10 mm and depth of 10–15 mm from the skin surface was 74% (57%) and 50% (25%) of the prescribed dose when using a 3 mm (9 mm) thickness scatter plate, respectively. As a result of this investigation on patient skin dose distributions we changed our patient treatments to use a 3 mm instead of a 9 mm thickness Acrylic scatter plate for clinically preferred skin depth dose coverage.

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3