Biophysical characterization of collimated and uncollimated fields in pencil beam scanning proton therapy

Author:

Nabha RacellORCID,De Saint-Hubert Marijke,Marichal Joachim,Esser Johannes,Van Hoey Olivier,Bäumer ChristianORCID,Verbeek NicoORCID,Struelens LaraORCID,Sterpin Edmond,Tabury Kevin,Marek Lukas,Granja CarlosORCID,Timmermann Beate,Vanhavere Filip

Abstract

Abstract Objective. The lateral dose fall-off in proton pencil beam scanning (PBS) technique remains the preferred choice for sparing adjacent organs at risk as opposed to the distal edge due to the proton range uncertainties and potentially high relative biological effectiveness. However, because of the substantial spot size along with the scattering in the air and in the patient, the lateral penumbra in PBS can be degraded. Combining PBS with an aperture can result in a sharper dose fall-off, particularly for shallow targets. Approach. The aim of this work was to characterize the radiation fields produced by collimated and uncollimated 100 and 140 MeV proton beams, using Monte Carlo simulations and measurements with a MiniPIX-Timepix detector. The dose and the linear energy transfer (LET) were then coupled with published in silico biophysical models to elucidate the potential biological effects of collimated and uncollimated fields. Main results. Combining an aperture with PBS reduced the absorbed dose in the lateral fall-off and out-of-field by 60%. However, the results also showed that the absolute frequency-averaged LET (LETF) values increased by a maximum of 3.5 keV μm−1 in collimated relative to uncollimated fields, while the dose-averaged LET (LETD) increased by a maximum of 7 keV μm−1. Despite the higher LET values produced by collimated fields, the predicted DNA damage yields remained lower, owing to the large dose reduction. Significance. This work demonstrated the dosimetric advantages of combining an aperture with PBS coupled with lower DNA damage induction. A methodology for calculating dose in water derived from measurements with a silicon-based detector was also presented. This work is the first to demonstrate experimentally the increase in LET caused by combining PBS with aperture, and to assess the potential DNA damage which is the initial step in the cascade of events leading to the majority of radiation-induced biological effects.

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference44 articles.

1. Comprehensive clinical commissioning and validation of the RayStation treatment planning system for proton therapy with active scanning and passive treatment techniques;Bäumer;Phys. Medica,2017

2. Collimated proton pencil-beam scanning for superficial targets: impact of the order of range shifter and aperture;Bäumer;Phys. Med. Biol.,2018

3. Evaluation of detectors for acquisition of pristine depth-dose curves in pencil beam scanning;Bäumer;J. Appl. Clin. Med. Phys.,2015

4. Clinical implementation of proton therapy using pencil-beam scanning delivery combined with static apertures;Bäumer;Front. Oncol.,2021

5. ESTAR, PSTAR, and ASTAR: Computer Programs for Calculating Stopping-Power and Range Tables for Electrons, Protons, and Helium Ions. National Institute of Standards and Technology, Gaithersburg, MD.;Berger,2017

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3