A portable primary-standard level graphite calorimeter for absolute dosimetry in clinical pencil beam scanning proton beams

Author:

Lourenço AORCID,Lee N,Charlwood F,Lambert J,Vera-Sánchez J A,Hussein M,Shipley D,Romano F,Lowe M,Clarke M,Lorentini S,Mazal AORCID,Pettingell J,Palmans HORCID,Thomas R

Abstract

Abstract Objective. To report the use of a portable primary standard level graphite calorimeter for direct dose determination in clinical pencil beam scanning proton beams, which forms part of the recommendations of the proposed Institute of Physics and Engineering in Medicine (IPEM) Code of Practice (CoP) for proton therapy dosimetry. Approach. The primary standard proton calorimeter (PSPC) was developed at the National Physical Laboratory (NPL) and measurements were performed at four clinical proton therapy facilities that use pencil beam scanning for beam delivery. Correction factors for the presence of impurities and vacuum gaps were calculated and applied, as well as dose conversion factors to obtain dose to water. Measurements were performed in the middle of 10 × 10 × 10 cm3 homogeneous dose volumes, centred at 10.0, 15.0 and 25.0 g·cm−2 depth in water. The absorbed dose to water determined with the calorimeter was compared to the dose obtained using PTW Roos-type ionisation chambers calibrated in terms of absorbed dose to water in 60Co applying the recommendations in the IAEA TRS-398 CoP. Main results. The relative dose difference between the two protocols varied between 0.4% and 2.1% depending on the facility. The reported overall uncertainty in the determination of absorbed dose to water using the calorimeter is 0.9% (k = 1), which corresponds to a significant reduction of uncertainty in comparison with the TRS-398 CoP (currently with an uncertainty equal or larger than 2.0% (k = 1) for proton beams). Significance. The establishment of a purpose-built primary standard and associated CoP will considerably reduce the uncertainty of the absorbed dose to water determination and ensure improved accuracy and consistency in the dose delivered to patients treated with proton therapy and bring proton reference dosimetry uncertainty in line with megavoltage photon radiotherapy.

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3