Material assignment for proton range prediction in Monte Carlo patient simulations using stopping-power datasets

Author:

Permatasari Felicia Fibiani,Eulitz Jan,Richter Christian,Wohlfahrt PatrickORCID,Lühr ArminORCID

Abstract

Abstract Motivation and objective. For each institute, the selection and calibration of the most suitable approach to assign material properties for Monte Carlo (MC) patient simulation in proton therapy is a major challenge. Current conventional approaches based on computed tomography (CT) depend on CT acquisition and reconstruction settings. This study proposes a material assignment approach, referred to as MATA (MATerial Assignment), which is independent of CT scanner properties and, therefore, universally applicable by any institute. Materials and methods. The MATA approach assigns material properties to the physical quantity stopping-power ratio (SPR) using a set of 40 material compositions specified for human tissues and linearly determined mass density. The application of clinically available CT-number-to-SPR conversion avoids the need for any further calibration. The MATA approach was validated with homogeneous and heterogeneous SPR datasets by assessing the SPR accuracy after material assignment obtained either based on dose scoring or determination of water-equivalent thickness. Finally, MATA was applied on patient datasets to evaluate dose differences induced by different approaches for material assignment and SPR prediction. Results. The deviation between the SPR after material assignment and the input SPR was close to zero in homogeneous datasets and below 0.002 (0.2% relative to water) in heterogeneous datasets, which was within the systematic uncertainty in SPR estimation. The comparison of different material assignment approaches revealed relevant differences in dose distribution and SPR. The comparison between two SPR prediction approaches, a standard look-up table and direct SPR determination from dual-energy CT, resulted in patient-specific mean proton range shifts between 1.3 mm and 4.8 mm. Conclusion. MATA eliminates the need for institution-specific adaptations of the material assignment. It allows for using any SPR dataset and thus facilitates the implementation of more accurate SPR prediction approaches. Hence, MATA provides a universal solution for patient modeling in MC-based proton treatment planning.

Funder

StrahlenSchutzSeminar in Thüringen e.V

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3