Processing of prompt gamma-ray timing data for proton range measurements at a clinical beam delivery

Author:

Werner Theresa,Berthold Jonathan,Hueso-González FernandoORCID,Koegler ToniORCID,Petzoldt Johannes,Roemer Katja,Richter ChristianORCID,Rinscheid Andreas,Straessner ArnoORCID,Enghardt Wolfgang,Pausch GuntramORCID

Abstract

Abstract In proton therapy, patients benefit from the precise deposition of the dose in the tumor volume due to the interaction of charged particles with matter. Currently, the determination of the beam range in the patient’s body during the treatment is not a clinical standard. This lack causes broad safety margins around the tumor, which limits the potential of proton therapy. To overcome this obstacle, different methods are under investigation aiming at the verification of the proton range in real time during the irradiation. One approach is the prompt gamma-ray timing (PGT) method, where the range of the primary protons is derived from time-resolved profiles (PGT spectra) of promptly emitted gamma rays, which are produced along the particle track in tissue. After verifying this novel technique in an experimental environment but far away from treatment conditions, the translation of PGT into clinical practice is intended. Therefore, new hardware was extensively tested and characterized using short irradiation times of 70 ms and clinical beam currents of 2 nA. Experiments were carried out in the treatment room of the University Proton Therapy Dresden. A pencil beam scanning plan was delivered to a target without and with cylindrical air cavities of down to 5 mm thickness. The range shifts of the proton beam induced due to the material variation could be identified from the corresponding PGT spectra, comprising events collected during the delivery of a whole energy layer. Additionally, an assignment of the PGT data to the individual pencil beam spots allowed a spot-wise analysis of the variation of the PGT distribution mean and width, corresponding to range shifts produced by the different air cavities. Furthermore, the paper presents a comprehensive software framework which standardizes future PGT analysis methods and correction algorithms for technical limitations that have been encountered in the presented experiments.

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference41 articles.

1. ROOT—an object oriented data analysis framework;Brun;Nucl. Instrum. Methods. Phys. Res. A,1997

2. 3D prompt gamma imaging for proton beam range verification;Draeger;Phys. Med. Biol.,2018

3. Charged hadron tumour therapy monitoring by means of PET;Enghardt;Nucl. Instrum. Methods Phys. Res. A,2004

4. Gamma-radiation imaging system based on the Compton effect;Everett;Proc. Inst. Electr. Eng.,1977

Cited by 46 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Secondary particle intensity for experimental range verification in carbon ion therapy;Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms;2024-10

2. An experimental validation of a filtering approach for prompt gamma prediction in a research proton treatment planning system;Physics in Medicine & Biology;2024-07-26

3. Stopping power and range estimations in proton therapy based on prompt gamma timing: motion models and automated parameter optimization;Physics in Medicine & Biology;2024-07-15

4. Proton spot dose estimation based on positron activity distributions with neural network;Medical Physics;2024-07-10

5. ‘Accurate proton range shift verification by using a two-layer dense-pixel LYSO compton camera prototype;Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment;2024-06

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3