More than one way to skin a dose volume: the impact of dose-surface map calculation approach on study reproducibility

Author:

Patrick Haley M,Kildea JohnORCID

Abstract

Abstract Objective. Dose-surface maps (DSMs) provide spatial representations of the radiation dose to organ surfaces during radiotherapy and are a valuable tool for identifying dose deposition patterns that are predictive of radiation toxicities. Over the years, many different DSM calculation approaches have been introduced and used in dose-outcome studies. However, little consideration has been given to how these calculation approaches may be impacting the reproducibility of studies in the field. Therefore, we conducted an investigation to determine the level of equivalence of DSMs calculated with different approaches and their subsequent impact on study results. Approach. Rectum and bladder DSMs were calculated for 20 prostate radiotherapy patients using combinations of the most common slice orientation and spacing styles in the literature. Equivalence of differently calculated DSMs was evaluated using pixel-wise comparisons and DSM features (rectum only). Finally, mock cohort comparison studies were conducted with DSMs calculated using each approach to determine the level of dosimetric study reproducibility between calculation approaches. Main results. We found that rectum DSMs calculated using the planar and non-coplanar orientation styles were non-equivalent in the posterior rectal region and that equivalence of DSMs calculated with different slice spacing styles was conditional on the choice of inter-slice distance used. DSM features were highly sensitive to choice of slice orientation style and DSM sampling resolution. Finally, while general result trends were consistent between the comparison studies performed using different DSMs, statisitically significant subregions and features could vary greatly in position and magnitude. Significance. We have determined that DSMs calculated with different calculation approaches are frequently non-equivalent and can lead to differing conclusions between studies performed using the same dataset. We recommend that the DSM research community work to establish consensus calculation approaches to ensure reproducibility within the field.

Funder

Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada

Canada Foundation for Innovation

Fonds de Recherche du Québec - Santé

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3