Helium radiography with a digital tracking calorimeter—a Monte Carlo study for secondary track rejection

Author:

Pettersen Helge Egil SeimeORCID,Volz LennartORCID,Sølie Jarle RamboORCID,Alme Johan,Barnaföldi Gergely Gábor,Barthel Rene,van den Brink Anthony,Borshchov Vyacheslav,Chaar Mamdouh,Eikeland Viljar,Genov Georgi,Grøttvik Ola,Helstrup HåvardORCID,Keidel Ralf,Kobdaj ChinoratORCID,van der Kolk Naomi,Mehendale Shruti,Meric IlkerORCID,Harald Odland Odd,Papp Gábor,Peitzmann Thomas,Piersimoni PierluigiORCID,Protsenko Maksym,Ur Rehman Attiq,Richter Matthias,Tefre Samnøy Andreas,Seco JoaoORCID,Shafiee Hesam,Songmoolnak Arnon,Tambave Ganesh,Tymchuk Ihor,Ullaland Kjetil,Varga-Kofarago Monika,Wagner Boris,Xiao RenZheng,Yang Shiming,Yokoyama Hiroki,Röhrich Dieter

Abstract

Abstract Radiation therapy using protons and heavier ions is a fast-growing therapeutic option for cancer patients. A clinical system for particle imaging in particle therapy would enable online patient position verification, estimation of the dose deposition through range monitoring and a reduction of uncertainties in the calculation of the relative stopping power of the patient. Several prototype imaging modalities offer radiography and computed tomography using protons and heavy ions. A Digital Tracking Calorimeter (DTC), currently under development, has been proposed as one such detector. In the DTC 43 longitudinal layers of laterally stacked ALPIDE CMOS monolithic active pixel sensor chips are able to reconstruct a large number of simultaneously recorded proton tracks. In this study, we explored the capability of the DTC for helium imaging which offers favorable spatial resolution over proton imaging. Helium ions exhibit a larger cross section for inelastic nuclear interactions, increasing the number of produced secondaries in the imaged object and in the detector itself. To that end, a filtering process able to remove a large fraction of the secondaries was identified, and the track reconstruction process was adapted for helium ions. By filtering on the energy loss along the tracks, on the incoming angle and on the particle ranges, 97.5% of the secondaries were removed. After passing through 16 cm water, 50.0% of the primary helium ions survived; after the proposed filtering 42.4% of the primaries remained; finally after subsequent image reconstruction 31% of the primaries remained. Helium track reconstruction leads to more track matching errors compared to protons due to the increased available focus strength of the helium beam. In a head phantom radiograph, the Water Equivalent Path Length error envelope was 1.0 mm for helium and 1.1 mm for protons. This accuracy is expected to be sufficient for helium imaging for pre-treatment verification purposes.

Funder

Nemzeti Kutatási Fejlesztési és Innovációs Hivatal

Trond Mohn Foundation

Norges Forskningsråd

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference61 articles.

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3