A mobile high-resolution gamma camera for therapeutic dose control during radionuclide therapy

Author:

Trigila CarlottaORCID,Verdier Marc-AntoineORCID,Pinot Laurent,Bouvet Francoise,Beaumont Tiffany Mélanie,Broggio David,Desbree Aurelie,Menard LaurentORCID

Abstract

Abstract Objective. Molecular radiotherapy is the most used treatment modality against malign and benign diseases of thyroid. In that context, the large heterogeneity of therapeutic doses in patients and the range of effects observed show that individualized dosimetry is essential for optimizing treatments according to the targeted clinical outcome. Approach. We developed a high-resolution mobile gamma camera specifically designed to improve the quantitative assessment of the distribution and biokinetics of 131I at patients’s bedside after treatment of thyroid diseases. The first prototype has a field of view of 5×5 cm2 and consists of a high-energy parallel-hole collimator made of 3D-printed tungsten, coupled to a 6 mm thick CeBr3 scintillator readout by an array of silicon photomultiplier detectors. The intrinsic and overall imaging performance of the camera was evaluated with 133Ba and 131I sources. In order to test its quantification capability in realistic clinical conditions, two different 3D-printed thyroid phantoms homogeneously filled with 131I were used. Both single view and conjugate view approaches have been applied, with and without scatter correction technique. Main Results. The camera exhibits high imaging performance with an overall energy resolution of 7.68±0.01%, a submillimetric intrinsic spatial resolution of 0.74±0.28 mm and a very low spatial distortion 0.15±0.10 mm. The complete calibration of the camera shows an overall spatial resolution of 3.14±0.03 mm at a distance of 5 cm and a corresponding sensitivity of 1.23±0.01 cps/MBq, that decreases with distance and slightly changes with source size, due to the influence of scattering. Activity recovery factors better than 97% were found with the thyroid phantoms. Significance. These preliminary results are very encouraging for the use of our camera as a tool for accurate quantification of absorbed doses and currently motivates the development of a fully operational clinical camera with a 10×10 cm2 field of view and improved imaging capabilities.

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3