Biaxial ultrasound driving technique for small animal blood–brain barrier opening

Author:

Pellow CarlyORCID,Li Siyun,Delgado Sagid,Pike G BruceORCID,Curiel LauraORCID,Pichardo SamuelORCID

Abstract

Abstract Biaxial driving can more efficiently convert electrical power to forward acoustic power in piezoelectric materials, and the interaction between the orthogonal electric fields can produce a combination of extensional and shear deformations as a function of the phase difference between them to allow dynamic steering of the beam with a single-element. In this study, we demonstrate for the first time the application of a single-element biaxially driven ring transducer in vivo for blood–brain barrier opening in mice, and compare it to that achieved with a conventional single-element highly focused (F# = 0.7) spherical transducer operating at a similar frequency. Transcranial focused ultrasound (0.45 MPa, 10 ms pulse length, 1 Hz repetition frequency, 30 s duration) was applied bilaterally to mice with a 40 μl/kg bolus of DefinityTM microbubbles, employing either a single-element biaxial ring (1.482 MHz, 10 mm inner diameter, 13.75 mm outer diameter) or spherical (1.5 MHz, 35 mm diameter, F# = 0.7; RK50, FUS Instruments) transducer on each side. Follow-up MRI scans (T1 pre- and post- 0.2 mmol/kg Gd injection, T2) were acquired to assess blood–brain barrier opening volume and potential damage. Compared to blood–brain barrier opening achieved with a conventional single-element spherical focused transducer, the opening volume achieved with a single-element biaxial ring transducer was 35% smaller (p = 0.002) with a device of a ring diameter of 40% the aperture size. Axial refocusing was further demonstrated with the single-element biaxial ring transducer, yielding a 1.63 mm deeper, five-fold larger opening volume (p = 0.048) relative to its small-focus mode. The biaxial ring transducer achieved a more localized opening compared to the spherical focused transducer under the same parameters, and further enabled dynamic axial refocusing with a single-element transducer with a smaller fabrication footprint.

Funder

Canada Foundation for Innovation

Canadian Institutes of Health Research

Natural Sciences and Engineering Research Council of Canada

Mitacs Accelerate and Elevate Programs

The Cumming School of Medicine Research Fund

Hotchkiss Brain Institute Evan's Family Donation

Eyes High Postdoctoral Scholarship

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Biaxial Excitation and Reception Method Applied to Ultrasound Imaging;IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control;2024-02

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3