Utilization of focused ultrasound for opening of the blood-nerve barrier

Author:

Umansky DanielORCID,Bing Chenchen,Chu Tak Ho,Alzahrani SaudORCID,Dunn Jeff F.,Pichardo SamuelORCID,Midha Rajiv

Abstract

Abstract Objective. Focused ultrasound (FUS) use with and without microbubbles (MB) for investigation of the blood-nerve barrier (BNB) within the peripheral nervous system (PNS) has been performed in this study. We evaluate the feasibility of BNB opening in a rodent sciatic nerve model by direct vision FUS treatment and provide preliminary results of magnetic resonance guided FUS (MRgFUS). Approach. Twenty rodent bilateral sciatic nerves were investigated. Rodents were treated using a benchtop FUS system to directly visualize nerve FUS studies. Definity MB, Evans blue dye (EB) and latex micro beads were injected during studies. Selected animals underwent further compound muscle action potential (CMAP) studies. Sonication peak pressure (MPa), width, duty-cycle and duration as well as MB concentration were varied to investigate effective pressure threshold. Further preliminary MRgFUS studies were performed on selected animals. Immunohistochemistry and histological analysis under florescent microscopy were performed at termination of experiments to verify treatment outcomes. Main results. Three ultrasound pressures and three microbubble concentrations at a single sonication frequency (476.5 kHz) were performed under direct open targeting. Histological analysis demonstrated nerve internal architecture disruption at 1.2 MPa with 166.7 μl kg−1 while 0.3 MPa, with 40 μl kg−1 MB concentration was the lower threshold for consistently observed disruption of the BNB without anatomical microarchitecture disruption. EB leakage was confirmed at the target region in histological evaluation of nerve following MB injection and FUS sonication. Supra-harmonic emissions were detected during FUS exposures following MB injection but not at baseline reference, indicating effective MB response and stable cavitation. CMAP amplitudes showed delayed onset latency and lower amplitudes in sonicated nerves compared to control nerves without evidence of complete conduction block, suggesting a transient BNB disruption, while at lower limit pressure subtle conduction changes were observed. In MRgFUS, targeted nerves demonstrated further contrast agent leak as well as supra-harmonic frequency detection. Significance. Opening of the BNB in the PNS was achieved using FUS and MB in a rodent model. Ongoing work aims to refine FUS parameters for drug delivery into the nerve after experimental transient BNB disruption.

Funder

Hotchkiss Brain Institute, University of Calgary

American Association of Neurological Surgeons

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3