Automation to facilitate optimisation of breast radiotherapy treatments using EPID-based in vivo dosimetry

Author:

Kirby JoshuaORCID,Chester KatherineORCID

Abstract

Abstract Objective. To use automation to facilitate the monitoring of each treatment fraction using an electronic portal imaging device (EPID) based in vivo dosimetry (IVD) system, allowing optimisation of breast radiotherapy delivery for individual patients and cohorts. Approach. A suite of in-house software was developed to reduce the number of manual interactions with the commercial IVD system, dosimetry check. An EPID specific pixel sensitivity map facilitated use of the EPID panel away from the central axis. Point dose difference and the change in standard deviation in dose were identified as useful dose metrics, with standard deviation used in preference to gamma in the presence of a systematic dose offset. Automated IVD was completed for 3261 fractions across 704 patients receiving breast radiotherapy. Main results. Multiple opportunities for treatment optimisation were identified for individual patients and across patient cohorts as a result of successful implementation of automated IVD. 5.1% of analysed fractions were out of tolerance with 27.1% of these considered true positives. True positive results were obtained on any fraction of treatment and if IVD had only been completed on the first fraction, 84.4% of true positive results would have been missed. This was made possible due to the automation that saved over 800 h of manual intervention and stored data in an accessible database. Significance. An improved EPID calibration to allow off-axis measurement maximises the number of patients eligible for IVD (36.8% of patients in this study). We also demonstrate the importance in selecting context-specific assessment metrics and how these can lead to a managable false positive rate. We have shown that the use of fully automated IVD facilitates use on every fraction of treatment. This leads to identification of areas for treatment improvement for both individuals and across a patient cohort, expanding the uses of IVD from simply gross error detection towards treatment optimisation.

Publisher

IOP Publishing

Reference34 articles.

1. In vivo dosimetry evaluation of semiconductor diodes and thermoluminscence detectors (TLDS) in advanced radiotherapy techniques;Al-Taee;Onkologia i Radioterapia,2020

2. Determination of the electronic portal imaging device pixel-sensitivity-map for quality assurance applications: I. Comparison of methods;Barnes;J. Appl. Clin. Med. Phys.,2022

3. Quantifying the performance of in vivo portal dosimetry in detecting four types of treatment parameter variations;Bojechko;Med. Phys.,2015

4. A new approach for the pixel map sensitivity (PMS) evaluation of an electronic portal imaging device (EPID);Boriano;J. Appl. Clin. Med. Phys.,2013

5. Assessing the impact of adaptations to the clinical workflow in radiotherapy using transit in vivo dosimetry;Bossuyt;Phys. Imaging Radiat. Oncol.,2023

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3