A Geant4 shielding design for the first US carbon multi-ion hybrid synchrotron facility

Author:

Dougherty Jingjing MORCID,Bolst David,Furutani Keith MORCID,Guatelli SusannaORCID,Liang XiaoyingORCID,Rosenfeld AnatolyORCID,Beltran Chris J

Abstract

Abstract The Mayo Clinic Florida Integrated Oncology Building will be the home of the first spot-scanning only carbon/proton hybrid therapy system by Hitachi, Ltd. It will provide proton beams up to kinetic energies of 230 MeV and carbon beams up to 430 MeV n−1 for clinical deployment. To provide adequate radiation protection, the Geant4 (v10.6) Monte Carlo toolkit was utilized to quantify the ambient dose equivalent at a 10 mm depth (H*(10)) for photons and neutrons. To perform accurate calculations of the ambient dose equivalent, three-dimensional computer-aided design files of the entire planned facility were imported into Geant4, as well as certain particle system components such as the bending magnets, fast Faraday cup, and gantry. Particle fluence was scored using 60 cm diameter spheres, which were strategically placed throughout areas of interests. Analytical calculations were performed as first-pass design checks. Major shielding slabs were optimized using Geant4 simulations iteratively, with more than 20 alternative designs evaluated within Geant4. The 430 MeV n−1 carbon beams played the most significant role in concrete thickness Requirements. The primary wall thickness for the carbon fixed beam room is 4 meters. The presence of the proton gantry structure in the simulation caused the ambient dose equivalent to increase by around 67% at the maze entrance, but a decrease in the high energy beam transport corridor. All shielding primary and secondary goals for clinical operations were met per state regulation and national guidelines.

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. The rationale for a carbon ion radiation therapy facility in Australia;Journal of Medical Radiation Sciences;2023-12-07

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3