Monte Carlo investigation of electron fluence perturbation in MRI-guided radiotherapy beams using six commercial radiation detectors

Author:

Cervantes YunuenORCID,Duane Simon,Bouchard Hugo

Abstract

Abstract With the integration of treatments with MRI-linacs to the clinical workflow, the understanding and characterization of detector response in reference dosimetry in magnetic fields are required. The external magnetic field perturbs the electron fluence. The degree of perturbation depends on the irradiation conditions and on the detector type. The purpose of this study is to evaluate the magnetic field impact on the electron fluence spectra in several detectors to provide a deeper understanding of detector response in these conditions. Monte Carlo calculations of the electron fluence are performed in six detectors (solid-state: PTW60012 and PTW60019, ionization chambers: PTW30013, PTW31010, PTW31021, and PTW31022) in water and irradiated by a 7 MV FFF photon beam with a small and a reference field, at 0 and 1.5 T. Three chamber axis orientations are investigated: parallel or perpendicular (either the Lorentz force pointing towards the stem or the tip) to the magnetic field and always perpendicular to the photon beam. One orientation for the solid-state detector is studied: parallel to the photon beam and perpendicular to the magnetic field. Additionally, electron fluence spectra are calculated in modified detector geometries to identify the underlying physical mechanisms behind the fluence perturbations. The total electron fluence in the Farmer chamber varies up to 1.24% and 5.12% at 1.5 T, in the parallel and perpendicular orientation, respectively. The interplay between the gyration radius and the Farmer chamber cavity length significantly affects the electron fluence in the perpendicular orientation. For the small-cavity chambers, the maximal variation in total electron fluence is 0.19% in the parallel orientation for the reference field. Significant small-field effects occur in these chambers; the magnetic field reduces the total electron fluence (with respect to the no field case) between 9.86% and 14.50%, depending on the orientation. The magnetic field strongly impacted the solid-state detectors in both field sizes, probably due to the high-Z components and cavity density. The maximal reductions of total electron fluence are 15.06 ± 0.09% (silicon) and 16.00 ± 0.07% (microDiamond). This work provides insights into detector response in magnetic fields by illustrating the interplay between several factors causing dosimetric perturbation effects: (1) chamber and magnetic field orientation, (2) cavity size and shape, (3) extracameral components, (4) air gaps and their asymmetry, (5) electron energy. Low-energy electron trajectories are more susceptible to change in magnetic fields, and are associated with detector response perturbation. Detectors with higher density and high-Z extracameral components exhibit more significant perturbations in the presence of a magnetic field, regardless of field size.

Funder

Natural Sciences and Engineering Research Council of Canada

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3