Gold nanoparticle detection and quantification in therapeutic MV beams via pair production

Author:

Brivio DORCID,Sajo EORCID,Zygmanski P

Abstract

Abstract Purpose. We propose a new detection method of gold nanoparticles (AuNP) in therapeutic megavoltage (MV) x-ray beams by means of coincidence counting of annihilation photons following pair production in gold. Methods. The proposed MV x-ray induced positron emission (MVIPE) imaging technique is studied by radiation transport computations using MCNP6 (3D) and CEPXS/ONEDANT (1D) codes for two water phantoms: a 35 cm slab and a similarly sized cylinder, both having a 5 cm AuNP filled region in the center. MVIPE is compared to the standard x-ray fluorescence computed tomography (XFCT). MVIPE adopts MV x-ray sources (Co-60, 2 MV, 6 MV, 6 MV with closed MLC and 15 MV) and relies on the detection of 511 keV photon-pairs. XFCT uses kilovoltage sources (100 kVp, 120 kVp and 150 kVp) and imaging is characterized by analysis of k α1,2 Au characteristic lines. Three levels of AuNP concentration were studied: 0.1%, 1% and 10% by weight. Results. Annihilation photons in the MVIPE technique originate both in the AuNP and in water along the x-ray beam path with significantly larger production in the AuNP-loaded region. MVIPE signal from AuNP is linearly increasing with AuNP concentration up to 10%wt, while XFCT signal reaches saturation due to self-absorption within AuNP. The production of annihilation photons is proportional to the MV source energy. MVIPE technique using a 15 MV pencil beam and 10 wt% AuNP detects about 4.5 × 103 511 keV-photons cm−2 at 90° w/r to the incident beam per 109 source photons cm−2; 500 of these come from AuNP. In contrast, the XFCT technique using 150 kVp detects only about 100 k α1-photons cm−2 per 109 source photons cm−2. Conclusions. In MVIPE, the number of annihilation photons produced for different MV-beam energies and AuNP concentrations is significantly greater than the k α1 photons generated in XFCT. Coincidence counting in MVIPE allows to avoid collimation, which is a major limiting factor in XFCT. MVIPE challenges include the filtering of Compton scatter and annihilation photons originating in water.

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Emerging Nanomaterials as Radio-Sensitizer in Radiotherapy;Harnessing Materials for X-ray Based Cancer Therapy and Imaging;2022

2. A deep learning approach to gold nanoparticle quantification in computed tomography;Physica Medica;2021-07

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3