Performance evaluation of the mouse version of the LabPET II PET scanner

Author:

Gaudin ÉmilieORCID,Thibaudeau Christian,Arpin Louis,Leroux Jean-Daniel,Toussaint Maxime,Beaudoin Jean-Francois,Cadorette Jules,Paillé Maxime,Pepin Catherine M,Koua Konin,Bouchard Jonathan,Viscogliosi Nicolas,Paulin Caroline,Fontaine Réjean,Lecomte RogerORCID

Abstract

Abstract The LabPET II is a new positron emission tomography technology platform designed to achieve submillimetric spatial resolution imaging using fully pixelated avalanche photodiodes-based detectors and highly integrated parallel front-end processing electronics. The detector was designed as a generic building block to develop devices for preclinical imaging of small to mid-sized animals and for clinical imaging of the human brain. The aim of this work is to assess the physical characteristics and imaging performance of the mouse version of LabPET II scanner following the NEMA NU4-2008 standard and using high resolution phantoms and in vivo imaging applications. A reconstructed spatial resolution of 0.78 mm (0.5 μ l) is measured close to the center of the radial field of view. With an energy window of 350 650 keV, the system absolute sensitivity is 1.2% and its maximum noise equivalent count rate reaches 61.1 kcps at 117 MBq. Submillimetric spatial resolution is achieved in a hot spot phantom and tiny bone structures were resolved with unprecedented contrast in the mouse. These results provide convincing evidence of the capabilities of the LabPET II technology for biomolecular imaging in preclinical research.

Funder

Natural Sciences and Engineering Research Council of Canada

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference45 articles.

1. NEMA NU-4 2008 performance evaluation of xtrim-PET: a prototype SiPM-based preclinical scanner;Amirrashedi;Med. Phys.,2019

2. Embedded real time digital signal processing unit for a 64-channel PET detector module;Arpin,2011

3. Performance evaluation of the Inveon dedicated PET preclinical tomograph based on the NEMA NU-4 standards;Bao;J. Nucl. Med.,2009

4. NEMA NU-4 performance evaluation of the IRIS PET/CT preclinical scanner;Belcari;IEEE Trans. Radiat. Plasma Med. Sci.,2017

5. Performance evaluation of the LabPET APD-based digital PET scanner;Bergeron;IEEE Trans. Nucl. Sci.,2009

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Challenges and rewards of in vivo synaptic density imaging, and its application to the study of depression;Neuropsychopharmacology;2024-07-22

2. Characterization of the BOLDPET optical prototype, an innovative Cherenkov detector for 511 keV γ radiation;Journal of Instrumentation;2024-07-01

3. Performance Comparison of DOI-Encoding PET Detectors Based on 1.1-mm Pitch BGO Arrays With Different Reflectors;IEEE Transactions on Radiation and Plasma Medical Sciences;2024-03

4. LabPET II scanner performances improvement: Thermal stability control based on FPGA;e-Prime - Advances in Electrical Engineering, Electronics and Energy;2023-12

5. Microliter in vivo Brain PET Imaging with the Ultra-High Resolution (UHR) Scanner;2023 IEEE Nuclear Science Symposium, Medical Imaging Conference and International Symposium on Room-Temperature Semiconductor Detectors (NSS MIC RTSD);2023-11-04

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3