Reducing 4DCBCT imaging dose and time: exploring the limits of adaptive acquisition and motion compensated reconstruction

Author:

Lau Benjamin K F,Reynolds TessORCID,Keall Paul J,Sonke Jan-JakobORCID,Vinod Shalini K,Dillon Owen,O’Brien Ricky T

Abstract

Abstract This study investigates the dose and time limits of adaptive 4DCBCT acquisitions (adaptive-acquisition) compared with current conventional 4DCBCT acquisition (conventional-acquisition). We investigate adaptive-acquisitions as low as 60 projections (∼25 s scan, 6 projections per respiratory phase) in conjunction with emerging image reconstruction methods. 4DCBCT images from 20 patients recruited into the adaptive CT acquisition for personalized thoracic imaging clinical study (NCT04070586) were resampled to simulate faster and lower imaging dose acquisitions. All acquisitions were reconstructed using Feldkamp–Davis–Kress (FDK), McKinnon–Bates (MKB), motion compensated FDK (MCFDK), motion compensated MKB (MCMKB) and simultaneous motion estimation and image reconstruction (SMEIR) algorithms. All reconstructions were compared against conventional-acquisition 4DFDK-reconstruction using Structural SIMilarity Index (SSIM), signal-to-noise ratio (SNR), contrast-to-noise-ratio (CNR), tissue interface sharpness diaphragm (TIS-D), tissue interface sharpness tumor (TIS-T) and center of mass trajectory (COMT) for difference in diaphragm and tumor motion. All reconstruction methods using 110-projection adaptive-acquisition (11 projections per respiratory phase) had a SSIM of greater than 0.92 relative to conventional-acquisition 4DFDK-reconstruction. Relative to conventional-acquisition 4DFDK-reconstruction, 110-projection adaptive-acquisition MCFDK-reconstructions images had 60% higher SNR, 10% higher CNR, 30% higher TIS-T and 45% higher TIS-D on average. The 110-projection adaptive-acquisition SMEIR-reconstruction images had 123% higher SNR, 90% higher CNR, 96% higher TIS-T and 60% higher TIS-D on average. The difference in diaphragm and tumor motion compared to conventional-acquisition 4DFDK-reconstruction was within submillimeter accuracy for all acquisition reconstruction methods. Adaptive-acquisitions resulted in faster scans with lower imaging dose and equivalent or improved image quality compared to conventional-acquisition. Adaptive-acquisition with motion compensated-reconstruction enabled scans with as low as 110 projections to deliver acceptable image quality. This translates into 92% lower imaging dose and 80% less scan time than conventional-acquisition.

Funder

Cancer Australia

National Health and Medical Research Council

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3