A 3D transfer learning approach for identifying multiple simultaneous errors during radiotherapy

Author:

van den Berg Kars,Wolfs Cecile J AORCID,Verhaegen FrankORCID

Abstract

Abstract Objective. Deep learning models, such as convolutional neural networks (CNNs), can take full dose comparison images as input and have shown promising results for error identification during treatment. Clinically, complex scenarios should be considered, with the risk of multiple anatomical and/or mechanical errors occurring simultaneously during treatment. The purpose of this study was to evaluate the capability of CNN-based error identification in this more complex scenario. Approach. For 40 lung cancer patients, clinically realistic ranges of combinations of various treatment errors within treatment plans and/or computed tomography (CT) images were simulated. Modified CT images and treatment plans were used to predict 2580 3D dose distributions, which were compared to dose distributions without errors using various gamma analysis criteria and relative dose difference as dose comparison methods. A 3D CNN capable of multilabel classification was trained to identify treatment errors at two classification levels, using dose comparison volumes as input: Level 1 (main error type, e.g. anatomical change, mechanical error) and Level 2 (error subtype, e.g. tumor regression, patient rotation). For training the CNNs, a transfer learning approach was employed. An ensemble model was also evaluated, which consisted of three separate CNNs each taking a region of interest of the dose comparison volume as input. Model performance was evaluated by calculating sample F1-scores for training and validation sets. Main results. The model had high F1-scores for Level 1 classification, but performance for Level 2 was lower, and overfitting became more apparent. Using relative dose difference instead of gamma volumes as input improved performance for Level 2 classification, whereas using an ensemble model additionally reduced overfitting. The models obtained F1-scores of 0.86 and 0.62 on an independent test set for Level 1 and Level 2, respectively. Significance. This study shows that it is possible to identify multiple errors occurring simultaneously in 3D dose verification data.

Funder

Varian Medical Systems

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3