Abstract
Abstract
Objective. X-ray microangiography provides detailed information on the internal structure and function of a biological subject. Its ability to evaluate the microvasculature of small animals is useful for acquiring basic and clinical medical knowledge. The following three conditions are necessary to attain detailed knowledge of biological functions: (1) high temporal resolution with sufficient x-ray intensity, (2) high spatial resolution, and (3) a wide field of view. Because synchrotron radiation microangiography systems provide high sapatial resolution and high temporal resolution as a result of their high x-ray intensity, such systems have been developed at various synchrotron radiation facilities, starting with the photon factory, leading to numerous medical discoveries. However, the three aforementioned functions are incompatible with the use of synchrotron radiation because the x-ray intensity decreases when a wide field of view is obtained. To overcome these problems, we developed a new x-ray optical system for microangiography in rats using synchrotron radiation x-rays. Approach. Instead of using monochromatic synchrotron radiation x-rays with a conventional double-crystal monochromator, we used white synchrotron radiation x-rays and an asymmetric Si crystal to simultaneously monochromatize the beam and widen the field of view. Main results. The intensity profile and spatial resolution of the x-ray images were then evaluated. The proposed x-ray optics increased the x-ray intensity and beam width by factors of 1.3 and 2.7, respectively, compared with those of conventional monochromatic x-rays. In addition, in vivo studies on microangiography in rats were performed to confirm that the images had sufficient intensity, spatial resolution, and field of view. One of a series of images taken at 50 ms frame−1 was shown as an example. Significance. This x-ray optics provides sufficient x-ray intensity, high spatial resolution, and a wide field of view. This technique is expected providing new insights into the evaluation of the vascular system.
Funder
Japan Society for the Promotion of Science
Subject
Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Practical design of the focusing system for transmission and reflection targets in X-ray sources;Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment;2024-10