IPEM topical report: results of a 2022 UK survey on the use of linac manufacturer integrated quality control (MIQC)

Author:

Pearson Michael,Barnes Michael PORCID,Brown Kirstie F,Hawthorn Karen,Stevens Simon WORCID,Kizhakke Veetil Rakesh,Weston StevenORCID,Whitbourn JR

Abstract

Abstract In recent years Radiotherapy linear accelerator (linac) vendors have developed their own integrated quality control (QC) systems. Such manufacturer-integrated-quality-control (MIQC) has the potential to improve both the quality and efficiency of linac QC but is currently being developed and utilised in the absence of specific best-practice guidance. An Institute of Physics and Engineering in Medicine working party was commissioned with a view to develop guidance for the commissioning and implementation of MIQC. This study is based upon a survey of United Kingdom (UK) radiotherapy departments performed by the working party. The survey was distributed to all heads of radiotherapy physics in the UK and investigated availability and uptake, community beliefs and opinions, utilisation, user experience and associated procedures. The survey achieved a 95% response rate and demonstrated strong support (>95%) for its use and further development. MIQC systems are available in 79% of respondents’ centres, and are in clinical use in 66%. The most common MIQC system was Varian MPC, in clinical use in 58% of responding centres, with CyberKnife AQA\E2E in 11%, TomoTherapy TQA in 8% and no users of Elekta Machine QA. A majority of users found their MIQC to be easy to use, reliable, and had five or more years of experience. Most users reported occasions of discrepancy in results between MIQC and conventional testing, but the majority considered this acceptable, indicating a false reporting frequency of quarterly or less. MIQC has shown value in preventative maintenance and early detection of machine deviations. There were inconsistent approaches in the utilisation and commissioning tests performed. Fewer than half of users perform QC of MIQC. 45% of responders have modified their QC processes with the introduction of MIQC, via replacement of conventional tests or reduction in their frequency. Future guidance is recommended to assist in the implementation of MIQC.

Publisher

IOP Publishing

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3