EXIRAD-HE: multi-pinhole high-resolution ex vivo imaging of high-energy isotopes

Author:

Nguyen Minh PhuongORCID,Goorden Marlies C,Beekman Freek J

Abstract

Abstract We recently developed a dedicated focusing multi-pinhole collimator for a stationary SPECT system that offers down to 120 µm (or 1.7 nL) spatial resolution SPECT images of cryo-cooled tissue samples (EXIRAD-3D). This collimator is suitable for imaging isotopes that are often used in small animal and diagnostic SPECT such as 125I (27 keV), 201Tl (71 keV), 99mTc (140 keV), and 111In (171 and 245 keV). The goal of the present work is to develop high-resolution pinhole imaging of tissue samples containing isotopes with high-energy photon emissions, for example, therapeutic alpha and beta emitters that co-emit high energy gammas (e.g. 213Bi (440 keV) and 131I (364 keV)) or 511 keV annihilation photons from PET isotopes. To this end, we optimise and evaluate a new high energy small-bore multi-pinhole collimator through simulations. The collimator-geometry was first optimised by simulating a Derenzo phantom scan with a biologically realistic activity concentration of 18F at two system sensitivities (0.30% and 0.60%) by varying pinhole placements. Subsequently, the wall thickness was selected based on reconstructions of a Derenzo phantom and a uniform phantom. The obtained collimators were then evaluated for 131I (364 keV), 213Bi (440 keV), 64Cu (511 keV), and 124I (511 + 603 keV) with biologically realistic activity concentrations, and also for some high activity concentrations of 18F, using digital resolution, mouse knee joint, and xenograft phantoms. Our results show that placing pinhole centres at a distance of 8 mm from the collimator inner wall yields good image quality, while a wall thickness of 43 mm resulted in sufficient shielding. The collimators offer resolutions down to 0.35 mm, 0.6 mm, 0.5 mm, 0.6 mm, and 0.5 mm when imaging 131I, 213Bi, 18F, 64Cu, and 124I, respectively, contained in tissue samples at biologically achievable activity concentrations.

Publisher

IOP Publishing

Subject

Radiology Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Reference38 articles.

1. Positron range-free and multi-isotope tomography of positron emitters;Beekman;Nat. Meth. submitted,2020

2. VECTor-6: broadband photon tomography takes the versatility of multi-modality preclinical imaging beyond the limits of PET-SPECT-CT and optical imaging;Beekman,2018

3. U-SPECT-I: a novel system for submillimeter-resolution tomography with radiolabeled molecules in mice;Beekman;J. Nucl. Med.,2005

4. Positron range estimations with PeneloPET;Cal-González;Phys. Med. Biol.,2013

5. Integration of SimSET photon history generator in GATE for efficient Monte Carlo simulations of pinhole SPECT;Chen;Med. Phys.,2008

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献