Abstract The goal of the present study was to propose a set of preliminary regional diagnostic reference levels (DRLs) for pediatric interventional cardiology (IC) procedures in Latin America and the Caribbean countries, classified by age and weight groups. The study was conducted in the framework of the Optimization of Protection in Pediatric Interventional Radiology in Latin America and the Caribbean program coordinated by the World Health Organization and the Pan American Health Organization in cooperation with the International Atomic Energy Agency. The first step of the program was focused on pediatric IC. Dose data from diagnostic and therapeutic procedures were collected between December 2020 and December 2021. Regional DRLs were set as the third quartile of patient dose data (kerma area product) collected in 18 hospitals from 10 countries in an initial sample of 968 procedures. DRLs were set for four age bands and five weight ranges. The values obtained for the four age bands (<1 yr, 1 to <5 yr, 5 to <10 yr and 10 to <16 yr) were 2.9, 6.1, 8.8 and 14.4 Gy cm2 for diagnostic procedures, and 4.0, 5.0, 10.0 and 38.1 Gy cm2 for therapeutic procedures, respectively. The values obtained for the five weight bands (<5 kg, 5 to <15 kg, 15 to <30 kg, 30 to <50 kg and 50 to <80 kg) were 3.0, 4.5, 8.1, 9.2 and 26.8 Gy cm2 for diagnostic procedures and 3.7, 4,3, 7.3, 16.1 and 53.4 Gy cm2 for therapeutic procedures, respectively. While initial data were collected manually as patient dose management systems (DMSs) were not available in most of the hospitals involved in the program, a centralized automatic DMS for the collection and management of patient dose indicators has now been introduced and is envisaged to increase the sample size. The possibility of alerting on high dose values and introducing corrective actions will help in optimization.

Funder

Pan American Health Organization

World Health Organization, Switzerland

International Atomic Energy Agency

Publisher

IOP Publishing

Subject

Public Health, Environmental and Occupational Health,Waste Management and Disposal,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3