Influence of tube and patient positioning in thoracoabdominal CT examinations on radiation exposure–towards a better patient positioning

Author:

Valentin Birte,Kamp Benedikt,Henke Jan,Ljimani Alexandra,Appel Elisabeth,Antoch Gerald,Steuwe AndreaORCID

Abstract

Abstract Although iso-centric patient positioning is enormously important in computed tomography (CT), it is complicated in thoracoabdominal imaging by the varying dimensions of the body. Patient positioning can affect the appearance of the patient on the localiser. Positioned too close to the x-ray tube, a patient appears considerably more voluminous. The goal of this study is to assess the difference in radiation exposure of combined chest and abdomen CT scans between scans with prior 0°- and 180°-localisers in conjunction with patient positioning. In this IRB-approved retrospective study, patients who had two routine thoracoabdominal CT scans on the same CT scanner, one with a prior 0°- and one with a prior 180°-localiser, were included. To evaluate the radiation exposure of the thoracoabdominal CT examination regarding the tube position during the localiser, volumetric computed tomography dose index (CTDIvol), size-specific dose estimate (SSDE), patient diameter and positioning within the iso-centre for three positions (heart, abdomen, femur level) were compared with regard to the tube position during the prior localiser. CT examinations of 114 patients were included. Despite similar patient weight and diameter between the two examinations, SSDE and CTDIvol was significantly larger (up to 73%) with 180°-localisers. Patient offset from the iso-centre ranged between −9 mm at the centre slice (abdomen level) to −43 mm at the most caudal slice at the pelvis (femur level), causing a significant magnification (p < 0.001) on 180°-localisers with a subsequent increase of the apparent attenuation. The results of this study emphasise the use of 0°-localisers in thoracoabdominal CTs, since 180°-localisers caused patient magnification with subsequent increase in radiation exposure. The advantage of 180°-localisers, namely reducing the dose in thyroid and breast, is eliminated if the dose of the CT scan increases significantly in the abdomen and pelvis.

Publisher

IOP Publishing

Subject

Public Health, Environmental and Occupational Health,Waste Management and Disposal,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3