Review of extremity dosimetry in nuclear medicine

Author:

Kollaard RobertORCID,Zorz AlessandraORCID,Dabin JérémieORCID,Covens PeterORCID,Cooke Jennie,Crabbé MelissaORCID,Cunha Lidia,Dowling Anita,Ginjaume MercèORCID,McNamara Leanne

Abstract

Abstract The exposure of the fingers is one of the major radiation protection concerns in nuclear medicine (NM). The purpose of this paper is to provide an overview of the exposure, dosimetry and protection of the extremities in NM. A wide range of reported finger doses were found in the literature. Historically, the highest finger doses are found at the fingertip in the preparation and dispensing of 18F for diagnostic procedures and 90Y for therapeutic procedures. Doses can be significantly reduced by following recommendations on source shielding, increasing distance and training. Additionally, important trends contributing to a lower dose to the fingers are the use of automated procedures (especially for positron emission tomography (PET)) and the use of prefilled syringes. On the other hand, the workload of PET procedures has substantially increased during the last ten years. In many cases, the accuracy of dose assessment is limited by the location of the dosimeter at the base of the finger and the maximum dose at the fingertip is underestimated (typical dose ratios between 1.4 and 7). It should also be noted that not all dosimeters are sensitive to low-energy beta particles and there is a risk for underestimation of the finger dose when the detector or its filter is too thick. While substantial information has been published on the most common procedures (using 99mTc, 18F and 90Y), less information is available for more recent applications, such as the use of 68Ga for PET imaging. Also, there is a need for continuous awareness with respect to contamination of the fingers, as this factor can contribute substantially to the finger dose.

Funder

PIONEER research programme

Publisher

IOP Publishing

Subject

Public Health, Environmental and Occupational Health,Waste Management and Disposal,General Medicine

Reference106 articles.

1. An overview on extremity dosimetry in medical applications;Vanhavere;Radiat. Prot. Dosim.,2008

2. Optimization of radiation protection of medical staff;Vanhavere,2012

3. Radiation dose to patients from radiopharmaceuticals. Addendum 3 to ICRP Publication 53. ICRP Publication 106. Annex E. Radiation exposure of hands in radiopharmacies: monitoring of doses and optimisation of protection;Ann. ICRP,2008

4. Occupational Exposure: With Special Reference to Skin Doses in Hands and Fingers

5. Strategies for assessment of doses to the tips of the fingers in nuclear medicine;Martin;J. Radiol. Prot.,2016