Effective doses and risks from medical diagnostic x-ray examinations for male and female patients from childhood to old age

Author:

Harrison John DORCID,Haylock Richard G EORCID,Jansen Jan T MORCID,Zhang WeiORCID,Wakeford RichardORCID

Abstract

Abstract The consideration of risks from medical diagnostic x-ray examinations and their justification commonly relies on estimates of effective dose, although the quantity is actually a health-detriment-weighted summation of organ/tissue-absorbed doses rather than a measure of risk. In its 2007 Recommendations, the International Commission on Radiological Protection (ICRP) defines effective dose in relation to a nominal value of stochastic detriment following low-level exposure of 5.7 × 10−2 Sv−1, as an average over both sexes, all ages, and two fixed composite populations (Asian and Euro-American). Effective dose represents the overall (whole-body) dose received by a person from a particular exposure, which can be used for the purposes of radiological protection as set out by ICRP, but it does not provide a measure that is specific to the characteristics of the exposed individual. However, the cancer incidence risk models used by ICRP can be used to provide estimates of risk separately for males and females, as a function of age-at-exposure, and for the two composite populations. Here, these organ/tissue-specific risk models are applied to estimates of organ/tissue-specific absorbed doses from a range of diagnostic procedures to derive lifetime excess cancer incidence risk estimates; the degree of heterogeneity in the distribution of absorbed doses between organs/tissues will depend on the procedure. Depending on the organs/tissues exposed, risks are generally higher in females and notably higher for younger ages-at-exposure. Comparing lifetime cancer incidence risks per Sv effective dose from the different procedures shows that overall risks are higher by about a factor of two to three for the youngest age-at-exposure group, 0–9 yr, than for 30–39 yr adults, and lower by a similar factor for an age-at-exposure of 60–69 yr. Taking into account these differences in risk per Sv, and noting the substantial uncertainties associated with risk estimates, effective dose as currently formulated provides a reasonable basis for assessing the potential risks from medical diagnostic examinations.

Publisher

IOP Publishing

Subject

Public Health, Environmental and Occupational Health,Waste Management and Disposal,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3