Feasibility of size-specific organ-dose estimates based on water equivalent diameter for common head CT examinations: a Monte Carlo study

Author:

Tahiri MORCID,Benameur Y,Mkimel MORCID,El Baydaoui R,Mesardi M R

Abstract

Abstract Computed tomography dose index (CTDI) is an unreliable dose estimate outside of the standard CTDI phantom diameters (16 and 32 cm). Size-specific dose estimate (SSDE) for head computed tomography (CT) examination was studied in the American Association of Physicists in Medicine Report 293 to provide SSDE coefficient factors based on water equivalent diameter as size metrics. However, it is limited to one protocol and for a fully irradiated organ. This study aimed to evaluate the dependency of normalized organ dose (ND) on water equivalent diameter as a size metric in three common protocols: routine head, paranasal sinus, and temporal bone. CTDIw measurements were performed for outlined protocols in the Siemens Emotion 16-slice-configuration scanner. Geant4 Application for Tomographic Emission Monte Carlo simulation platform, coupled with ten GSF patient models, was used to estimate organ doses. CT scanner system was modeled. Helical CT scans were simulated using constructor scan parameters and calculated scan lengths of each patient model. Organ doses provided by simulations were normalized to CTDIvol. The water equivalent diameters (D w) of patient models were obtained via relationships between D w and both effective diameter for a sample of patients’ data.NDs received by fully, partially, and non-directly irradiated organs were then reported as a function of D w. For fully irradiated organs, brain (R 2 > 0.92), eyes (R 2 > 0.88), and eye lens (R 2 > 0.89) correlate well with D w. For the rest of the results, a poor correlation was observed. For partially irradiated organs, the exception was scalp (R 2 = 0.93) in temporal bone CT. For non-directly irradiated organs, the exception was thyroid (R 2 > 0.90) and lungs (R 2 > 0.91) in routine head CT. ND correlates well in routine head CT than other protocols. For the most part, no relationship seems to exist between R 2 and scan percentage coverage. The results have revealed additional factors that may influence the ND and D w relationship, which explains the need for more studies in the future to investigate the effect of scan conditions and organ anatomy variation.

Publisher

IOP Publishing

Subject

Public Health, Environmental and Occupational Health,Waste Management and Disposal,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3