Abstract The objective of this investigation is to assess the impact of supplementary lead curtains on the reduction of radiation dose exposure to operators during coronary interventional procedures. Seven standard positions during coronary angiography (foot, right foot, head, left foot, left lateral, left head, and right lateral) were simulated on a standard anthropomorphic phantom with radial artery access. Measurements were taken at two different heights, 125 cm and 155 cm, and dosimeters were used to measured surface incident dose rates for the first and second operators, both with and without additional lead curtains at various positions. Each position was measured 20 times, and arithmetic means were computed. A t-test was utilised to compare dose rates with and without supplementary lead curtains, as well as dose rates with additional lead curtains at varying heights. The finding indicate that the dose rates of the first operator with supplementary lead curtains were not significantly lower compared to those without, except for the 125 cm head and left foot positions and the 155 cm head position with the additional lead curtain edge 10 cm below the umbilical level (t umbilical = 0.9, 0.4, 0.5, P > 0.05). The dose rates of the second operator with additional lead curtains were significantly lower than those without, with statistically significant differences (P < 0.05). The arithmetic mean dose rates for the first and second operators at each position were lowest when the upper edge of the additional lead curtain was situated 10 cm above the umbilical level. Employing supplementary lead curtains during coronary interventions effectively reduces radiation doses received by operators. The protective effect is enhanced when the additional lead curtain is closer to the irradiation field. Hence, it is recommended that additional curtains be employed judiciously, while ensuring that clinical procedures are not impeded, in order to effectively mitigate the radiation exposure of operators.

Funder

Assessing Lead Curtains’ Impact on Radiation Protection in Coronary Interventions

Publisher

IOP Publishing

Subject

Public Health, Environmental and Occupational Health,Waste Management and Disposal,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3