Typical doses and typical values for fluoroscopic diagnostic and interventional procedures

Author:

Tristram JulianaORCID,Steuwe AndreaORCID,Kröpil Feride,Thomas Christoph,Rubbert ChristianORCID,Antoch Gerald,Boos Johannes

Abstract

Abstract To implement typical doses (TD) and typical values (TV) for fluoroscopic diagnostic and interventional procedures. A total of 3811 fluoroscopic procedures performed within 34 months on three devices were included in this retrospective study. Dose-, patient- and procedure-related information were extracted using the institutional dose management system (DMS). TD/TV were defined as median dose and calculated for the five most frequent procedures per device for dose area product (DAP), cumulative air kerma (CAK) and fluoroscopy time (FT). National diagnostic reference levels and other single facility studies were compared to our results. Additionally, the five procedures with the highest doses of each device were analysed. To evaluate the data coverage of the DMS compared to the picture archiving and communication system (PACS), procedure lists were extracted from the PACS and compared to the procedure information extracted from the DMS. TD/TV for 15 procedures were implemented. Among all devices, TD for DAP ranged between 0.6 Gycm2 for port catheter control (n = 64) and 145.9 Gycm2 for transarterial chemoembolisation (n = 84). TD for CAK ranged between 5 mGy for port catheter control and 1397 mGy for aneurysm treatment (n = 129) and TV for FT ranged between 0.3 min for upper cavography (n = 67) and 51.4 min for aneurysm treatment. TD for DAP and CAK were lower or within the range of other single facility studies. The five procedures with the highest median DAP per device were identified, 6 of 15 procedures were also found to be among the most frequent procedures. Data coverage of the DMS compared to the PACS ranged between 71% (device 2, stroke treatment) and 78% (device 1, lower limb angiography) for the most common procedure per device. Thus, in 22%–29% of cases dose data of the performed procedure was not transferred into the DMS. We implemented TD/TV for fluoroscopic diagnostic and interventional procedures which enable a comprehensive dose analysis and comparison with previously published values.

Publisher

IOP Publishing

Subject

Public Health, Environmental and Occupational Health,Waste Management and Disposal,General Medicine

Reference34 articles.

1. Establishing guidance levels in x-ray guided medical interventional procedures: a pilot study,2009

2. Frequency and doses of diagnostic and interventional x-ray applications: trends between 2007 and 2014;Nekolla;Radiologe,2017

3. Patient dose reference levels for interventional radiology: a national approach;Vano;Cardiovasc. Intervent. Radiol.,2009

4. URN urn: nbn:de:0221–2018112017017,2016

5. 2013/59/Euratom of 5 December 2013 laying down basic safety standards for protection against the dangers arising from exposure to ionising radiation, and repealing directives 89/618/Euratom, 90/641/Euratom, 96/29/Euratom, 97/43/Euratom and 2003/122/Euratom;Offic. J. EU 2014,2013