Abstract A survey was performed of the available gamma camera models and whole-body counters (WBCs) in Sweden, revealing that there are about 75 gamma cameras and 15 WBCs currently in operation in Sweden. One of the most common gamma camera models (GE Discovery NM/CT 670 Pro), with the collimators removed, was calibrated for 152Eu, 137Cs, 60Co and 40K in three different measurement geometries (supine, close-up sitting and distant sitting) for six different phantom sizes (12–110 kg). Minimum detectable activities (MDAs) were calculated for the gamma camera and a typical WBC, both at the Sahlgrenska University Hospital in Gothenburg, Sweden. An energy window of 30–510 keV was used to calibrate the gamma camera. The calibration factors for this gamma camera for supine and close-up sitting geometry, including all phantom sizes, were 138–208 cps kBq−1 for 152Eu, 63–83 cps kBq−1 for 137Cs and 99–126 cps kBq−1 for 60Co; the MDAs were 50–73 Bq for 152Eu, 125–198 Bq for 137Cs and 83–105 Bq for 60Co. The International Commission on Radiological Protection dose coefficients for members of the public were used to calculate the committed effective doses (CEDs) corresponding to the MDAs, showing that CEDs down to a few μSv can be estimated with this gamma camera for the inhalation of aerosols of absorption type M. The distant sitting geometry was used to enable the estimation of higher contamination levels, and a hypothetical maximum CED was calculated. This was shown to be 256–2000 mSv, depending on the radionuclide and phantom size. However, further investigations are needed into the dead time losses for higher activity levels for the radionuclides studied. The results show that the use of gamma cameras for radiological triage and, in some cases, to estimate the internal activity of relevant radionuclides in radiological and nuclear events, is feasible.

Funder

Swedish Radiation Safety Authority

Swedish Civil Contingencies Agency

Publisher

IOP Publishing

Subject

Public Health, Environmental and Occupational Health,Waste Management and Disposal,General Medicine

Reference23 articles.

1. An overview of internal dose estimation using whole-body counters in Fukushima Prefecture;Miyazaki;Fukushima J. Med. Sci.,2014

2. Sources, effects and risks of ionizing radiation,2020

3. Exposures and effects of the Chernobyl accident,2000

4. Radiation monitoring for protection of the public after major releases of radionuclides to the environment;J. ICRU,2015

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. The human dimension: the Bernard Wheatley Award for 2023;Journal of Radiological Protection;2024-05-16

2. Calibration of medical gamma cameras for estimation of internal contamination from 137Cs;Journal of Radiological Protection;2024-04-04

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3