Establishment of national diagnostic reference levels for computed tomography procedures in Sri Lanka: first nationwide dose survey

Author:

Amalaraj T,Satharasinghe DumindaORCID,Pallewatte Aruna,Jeyasugiththan JeyasingamORCID

Abstract

Abstract The main purpose of this study was to establish for the first time national diagnostic reference levels (NDRLs) for common computed tomography (CT) procedures in Sri Lanka. Patient morphometric data, exposure parameters and dose data such as volume CT dose index (CTDI v o l ) and dose–length product (DLP) were collected from 5666 patients who underwent 22 types of procedure. The extreme dose values were filtered before analysis to ensure that the data come from standard size patients. The median of the dose distribution was calculated for each institution, and the third quartile value of the median distribution was considered as the NDRL. Based on the inclusion and exclusion criteria, data from 4592 patients and 17 procedure types were considered for establishment of a NDRL, covering 41% of the country’s CT machines. The proposed NDRLs based on CTDI v o l and DLP were: non-contrast-enhanced (NC) head, 82.2 mGy/1556 mGy cm; contrast-enhanced (CE) head, 82.2 mGy/1546 mGy cm; chest NC, 7.4 mGy/350 mGy cm; chest CE, 8.3 mGy/464 mGy cm; abdomen NC, 10.5 mGy/721 mGy cm; abdomen arterial (A) phase, 13.4 mGy/398 mGy cm; abdomen venous (V) phase, 10.8 mGy/460 mGy cm; abdomen delay (D) phase, 12.6 mGy/487 mGy cm; sinus NC, 30.2 mGy/452 mGy cm; lumbar spine NC, 24.1 mGy/1123 mGy cm; neck NC, 27.5 mGy/670 mGy cm; high-resolution CT of chest, 10.3 mGy/341 mGy cm; kidneys ureters and bladder NC, 19.4 mGy/929 mGy cm; chest to pelvis (CAP) NC, 10.8 mGy/801 mGy cm; CAP A, 10.4 mGy/384 mGy cm; CAP V, 10.5 mGy/534 mGy cm; CAP D, 16.8 mGy/652 mGy cm. Although the proposed NDRLs are comparable with those of other countries, the observed broad dose distributions between the CT machines within Sri Lanka indicate that dose optimisation strategies for the country should be implemented for most of the CT facilities.

Publisher

IOP Publishing

Subject

Public Health, Environmental and Occupational Health,Waste Management and Disposal,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3