Setting Scottish diagnostic reference levels for mammography incorporating both craniocaudal and oblique projections between 30 and 80 mm

Author:

Weir AORCID,Schofield K AORCID,McCurrach AORCID

Abstract

Abstract Optimisation must be carried out on all medical radiological units to ensure doses are as low as reasonably practicable, consistent with the intended purpose. To achieve this, population doses must be estimated and diagnostic reference levels (DRLs) set. For mammography examinations, mean glandular doses (MGDs) are calculated for this purpose. The average MGD per unit is compared to the national mammography DRL, which is applicable to compressed breast thicknesses (CBTs) of 50–60 mm for oblique (OB) views only and set using data from screening units. It is the purpose of this work to assess planar MGDs across Scotland and set DRLs based on data collected from all screening and symptomatic units across Scotland, considering craniocaudal (CC) and OB views and a wider range of CBTs. Data from the most recent dose audit (spanning 20152017) for 67 mammography x-ray units were collated and analysed (26 195 images). No large differences between MGD of CC and OB views were found when considering specific CBT ranges (median difference 2.6%). There was, however, a significant difference between screening and symptomatic data (19%). As expected, MGD increased with CBT and there were significant differences in MGD between manufacturers. From the data analysed, Scottish DRLs were set based on 95th percentile values for digital mammography units for three CBT ranges (30–49, 50–60 and 61–80 mm): 1.3, 1.8 and 2.6 mGy respectively. These values consider OB and CC views collectively. Fifth percentile values are quoted to highlight units at greater risk of insufficient image quality. These MGD values, together with image quality assessments, will facilitate optimisation across Scotland. Results show that use of different CBT ranges and inclusion of CC views increases the number of images included in dose audit data analysis from approximately 12%92%, which is substantially more representative of the population.

Publisher

IOP Publishing

Subject

Public Health, Environmental and Occupational Health,Waste Management and Disposal,General Medicine

Reference44 articles.

1. Statutory Instrument Number 1322,2017

2. Statutory Instrument Number 17,2018

3. Further factors for the estimation of mean glandular dose using the United Kingdom, European and IAEA dosimetry protocols;Dance;Phys. Med. Biol.,2009

4. Recommended Standards for the Routine Performance Testing of Diagnostic X-Ray Systems,2005

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3