Use of real-time electronic extremity dosimeters for monitoring and optimisation of radiopharmacy technique

Author:

Cournane SORCID,McCavana J,Maguire D,Tutty L,Harris L,Lucey J,Kenneally C

Abstract

Abstract Radiopharmacy staff members are subject to extremity radiation doses, particularly to the fingertips. Dosemeters, such as, thermoluminescent detectors (TLDs) are currently used for monitoring fingertip doses. This study aimed to use real-time dosemeters to monitor radiopharmacy extremity doses to identify specific procedural steps associated with higher fingertip doses and, subsequently, reduce dose through promotion of optimised radiation protection practises. Five radiopharmacy operators were monitored using an ED3 active extremity dosemeter with a detector attached to each tip of the index fingers. Dose rate and accumulated dose data were matched to the handled radioactivity data, of 99mTc-labelled radiopharmaceuticals only, with the dose per activity (μSv MBq−1) calculated for each step. Once baseline dose data was established, an educational session identified technique adjustments toward improved radiation protection. A subsequent monitored session was undertaken with the dose data compared to quantify changes in operator doses. Radiopharmacy steps which significantly contributed to extremity doses were identified. The average accumulated dose per activity across all procedural steps for the 99mTc-labelled radiopharmaceuticals for all operators before the educational session was 0.042 ± 0.045 μSv MBq−1 and 0.042 ± 0.041 μSv MBq−1 (n = 89) for non-dominant and dominant index fingertips, respectively, and 0.030 ± 0.044 μSv MBq−1 and 0.031 ± 0.032 μSv MBq−1 (n = 97), respectively, afterwards. Overall, there was an average 40.7% reduction in the total extremity dose received after the educational session. Real-time electronic extremity dosemeters for monitoring radiopharmacy extremity dose presented as a useful tool for incorporation into radiation protection education and training, towards optimised radiopharmacy technique.

Publisher

IOP Publishing

Reference13 articles.

1. Finger doses for staff handling radiopharmaceuticals in nuclear medicine;Pant;J. Nucl. Med. Technol.,2006

2. Hand exposure to ionising radiation of nuclear medicine workers;Wrzesień;Radiat. Prot. Dosim.,2008

3. External radiation exposure of personnel in nuclear medicine from 18F, 99mTC and 131I with special reference to fingers, eyes and thyroid;Leide-Svegborn;Radiat. Prot. Dosim.,2012

4. Strategies for assessment of doses to the tips of the fingers in nuclear medicine;Martin;J. Radiol. Prot.,2016

5. Evaluation of a real-time semiconductor dosimeter and measurement of finger dose in nuclear medicine departments;Fujibuchi;Radiol. Phys. Technol.,2010

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3