Multimodal wearable EEG, EMG and accelerometry measurements improve the accuracy of tonic-clonic seizure detection

Author:

Zhang JingweiORCID,Swinnen LaurenORCID,Chatzichristos ChristosORCID,Broux Victoria,Proost Renee,Jansen Katrien,Mahler Benno,Zabler NicolasORCID,Epitashvilli Nino,Dümpelmann MatthiasORCID,Schulze-Bonhage Andreas,Schriewer Elisabeth,Ermis Ummahan,Wolking Stefan,Linke Florian,Weber Yvonne,Symmonds Mkael,Sen Arjune,Biondi Andrea,Richardson Mark P,I Abuhaiba Sulaiman,Silva Ana Isabel,Sales Francisco,Vértes Gergely,Paesschen Wim Van,Vos Maarten De

Abstract

Abstract Objective. This paper aims to investigate the possibility of detecting tonic-clonic seizures (TCSs) with behind-the-ear, two-channel wearable electroencephalography (EEG), and to evaluate its added value to non-EEG modalities in TCS detection. Methods. We included 27 participants with a total of 44 TCSs from the European multicenter study SeizeIT2. The wearable Sensor Dot (Byteflies) was used to measure behind-the-ear EEG, electromyography (EMG), electrocardiography, accelerometry (ACC) and gyroscope. We evaluated automatic unimodal detection of TCSs, using sensitivity, precision, false positive rate (FPR) and F1-score. Subsequently, we fused the different modalities and again assessed performance. Algorithm-labeled segments were then provided to two experts, who annotated true positive TCSs, and discarded false positives. Results. Wearable EEG outperformed the other single modalities with a sensitivity of 100% and a FPR of 10.3/24 h. The combination of wearable EEG and EMG proved most clinically useful, delivering a sensitivity of 97.7%, an FPR of 0.4/24 h, a precision of 43%, and an F1-score of 59.7%. The highest overall performance was achieved through the fusion of wearable EEG, EMG, and ACC, yielding a sensitivity of 90.9%, an FPR of 0.1/24 h, a precision of 75.5%, and an F1-score of 82.5%. Conclusions. In TCS detection with a wearable device, combining EEG with EMG, ACC or both resulted in a remarkable reduction of FPR, while retaining a high sensitivity. Significance. Adding wearable EEG could further improve TCS detection, relative to extracerebral-based systems.

Funder

EIT Health

FWO Research Project

Flemish Government

KU Leuven

Publisher

IOP Publishing

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Learning Robust Representations of Tonic-Clonic Seizures With Cyclic Transformer;IEEE Journal of Biomedical and Health Informatics;2024-06

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3