Analysis of respiratory kinematics: a method to characterize breaths from motion signals

Author:

Ashe William B,Innis Sarah E,Shanno Julia N,Hochheimer Camille J,Williams Ronald D,Ratcliffe Sarah J,Moorman J RandallORCID,Gadrey Shrirang M

Abstract

Abstract Objective. Breathing motion (respiratory kinematics) can be characterized by the interval and depth of each breath, and by magnitude-synchrony relationships between locations. Such characteristics and their breath-by-breath variability might be useful indicators of respiratory health. To enable breath-by-breath characterization of respiratory kinematics, we developed a method to detect breaths using motion sensors. Approach. In 34 volunteers who underwent maximal exercise testing, we used 8 motion sensors to record upper rib, lower rib and abdominal kinematics at 3 exercise stages (rest, lactate threshold and exhaustion). We recorded volumetric air flow signals using clinical exercise laboratory equipment and synchronized them with kinematic signals. Using instantaneous phase landmarks from the analytic representation of kinematic and flow signals, we identified individual breaths and derived respiratory rate (RR) signals at 1 Hz. To evaluate the fidelity of kinematics-derived RR, we calculated bias, limits of agreement, and cross-correlation coefficients (CCC) relative to flow-derived RR. To identify coupling between kinematics and flow, we calculated the Shannon entropy of the relative frequency with which flow landmarks were distributed over the phase of the kinematic cycle. Main Results. We found good agreement in the kinematics-derived and flow-derived RR signals [bias (95% limit of agreement) = 0.1 (± 7) breaths/minute; CCC median (IQR) = 0.80 (0.48–0.91)]. In individual signals, kinematics and flow were well-coupled (entropy 0.9–1.4 across sensors), but the relationship varied within (by exercise stage) and between individuals. The final result was that the flow landmarks did not consistently localize to any particular phase of the kinematic signals (entropy 2.2–3.0 across sensors). Significance. The Analysis of Respiratory Kinematics method can yield highly resolved respiratory rate signals by separating individual breaths. This method will facilitate characterization of clinically significant breathing motion patterns on a breath-by-breath basis. The relationship between respiratory kinematics and flow is much more complex than expected, varying between and within individuals.

Funder

The Ivy Foundation

University of Virginia, Center for Engineering in Medicine

University of Virginia, Division of General, Geriatric, Palliative and Hospital Medicine

Publisher

IOP Publishing

Subject

Physiology (medical),Biomedical Engineering,Physiology,Biophysics

Reference35 articles.

1. ATS/ERS Statement on respiratory muscle testing;Am. J. Respir. Crit. Care Med.,2002

2. An efficient algorithm for spectral analysis of heart rate variability;Berger;IEEE Trans. Biomed. Eng.,1986

3. Perceived exertion as an indicator of somatic stress;Borg;Scand. J. Rehabil. Med.,1970

4. Opioid-induced respiratory depression is associated with increased tidal volume variability;Bouillon;Eur. J. Anaesthesiol.,2003

5. Respiratory rate and pattern;Braun,1990