4D flow MRI: impact of region of interest size, angulation and spatial resolution on aortic flow assessment

Author:

Casciaro M E,Pascaner A F,Guilenea F N,Alcibar J,Gencer U,Soulat G,Mousseaux E,Craiem D

Abstract

Abstract Objectives. In cardiovascular magnetic resonance, the 3D time-resolved phase-contrast technique, also known as 4D flow, is gaining increasing attention due to applications that exploit three-directional velocity encoding throughout the cardiac cycle. Blood flow volume assessment usually requires an expert to draw regions of interest (ROI) around the vessel cross section, whereas the errors involved in this estimation have not been thoroughly investigated. Our objective is to quantify the influence of ROI sizing, angulation and spatial resolution of the reconstructed plane employed in blood flow measurements using 4D flow. Approach. Three circular ROIs were drawn around the ascending, arch and descending aorta of healthy volunteers (n = 27) and patients with a dilated ascending aorta or bicuspid valve (n = 37). We applied systematic changes of ROI diameter (up to ±10%), tilt angle (up to ±25°) and spatial resolution (from 0.25 to 2 mm) of the reconstructed oblique planes, calculating the effects on net, forward and backward blood flow volumes. Main results. Patients had a larger ascending aorta than healthy volunteers with similar ages and male sex proportion (60 ± 15 y.o. vs 58 ± 16 y.o. and 84% vs 70%, respectively). Higher forward and backward flow volumes were observed in the ascending aorta and the aortic arch of the patients with respect to controls (p < 0.001), whereas net volumes were similar: 74.0 ± 20.8 ml versus 75.7 ± 21.8 ml (p = 0.37), respectively. The ascending aorta was the most sensitive to ROI modifications. Changes of ±10% in the ROI diameter and ±25° in tilt angles produced flow volume differences of up to 9 ml (10%) and 18 ml (15%) in controls and patients, respectively. Modifying the reconstructed planes spatial resolution produced flow volume changes below 2 ml. Significance. Since the setting of the ROI size and plane angle could produce errors that represent up to 20% of the forward and/or backward aortic flow volume, a good standardization for vessel segmentation and plane positioning is desirable.

Funder

Fondo para la Investigación Científica y Tecnológica

Consejo Nacional de Investigaciones Científicas y Técnicas

Publisher

IOP Publishing

Subject

Physiology (medical),Biomedical Engineering,Physiology,Biophysics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3