Abstract

Abstract Objective. Mask positive-pressure ventilation could lead to lung ventilation inhomogeneity, potentially inducing lung function impairments, when compared with spontaneous breathing. Lung ventilation inhomogeneity can be monitored by chest electrical impedance tomography (EIT), which could increase our understanding of mask ventilation-derived respiratory mechanics. We hypothesized that the two-handed mask holding ventilation technique resulted in better lung ventilation, reflected by respiratory mechanics, when compared with the one-handed mask holding technique. Approach. Elective surgical patients with healthy lungs were randomly assigned to receive either one-handed mask holding (one-handed group) or two-handed mask holding (two-handed group) ventilation. Mask ventilation was performed by certified registered anesthesiologists, during which the patients were mechanically ventilated using the pressure-controlled mode. EIT was used to assess respiratory mechanics, including ventilation distribution, global and regional respiratory system compliance (C RS), expiratory tidal volume (TVe) and minute ventilation volume. Hemodynamic parameters and the PaO2-FiO2 ratio were also recorded. Main results. Eighty adult patients were included in this study. Compared with spontaneous ventilation, mask positive-pressure ventilation caused lung ventilation inhomogeneity with both one-handed(global inhomogeneity index: 0.40 ± 0.07 versus 0.50 ± 0.15; P < 0.001) and two-handed mask holding (0.40 ± 0.08 versus 0.50 ± 0.13; P < 0.001). There were no differences in the global inhomogeneity index (P = 0.948) between the one-handed and two-handed mask holding. Compared with the one-handed mask holding, the two-handed mask holding was associated with higher TVe (552.6 ± 184.2 ml versus 672.9 ± 156.6 ml, P = 0.002) and higher global C RS (46.5 ± 16.4 ml/cmH2O versus 53.5 ± 14.5 ml/cmH2O, P = 0.049). No difference in PaO2-FiO2 ratio was found between both holding techniques (P = 0.743). Significance. The two-handed mask holding technique could not improve the inhomogeneity of lung ventilation when monitored by EIT during mask ventilation although it obtained larger expiratory tidal volumes than the one-handed mask holding technique.

Funder

Science and Technology Commission of Shanghai Municipality

Publisher

IOP Publishing

Subject

Physiology (medical),Biomedical Engineering,Physiology,Biophysics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3