Quantifying the accuracy of inter-beat intervals acquired from consumer-grade photoplethysmography wristbands using an electrocardiogram-aided information-based similarity approach

Author:

Cui XingranORCID,Wang Jing,Xue Shan,Qin Zeguang,Peng Chung-KangORCID

Abstract

Abstract Objective. Although inter-beat intervals (IBI) and the derived heart rate variability (HRV) can be acquired through consumer-grade photoplethysmography (PPG) wristbands and have been applied in a variety of physiological and psychophysiological conditions, their accuracy is still unsatisfactory. Approach. In this study, 30 healthy participants concurrently wore two wristbands (E4 and Honor 5) and a gold-standard electrocardiogram (ECG) device under four conditions: resting, deep breathing with a frequency of 0.17 Hz and 0.1 Hz, and mental stress tasks. To quantitatively validate the accuracy of IBI acquired from PPG wristbands, this study proposed to apply an information-based similarity (IBS) approach to quantify the pattern similarity of the underlying dynamical temporal structures embedded in IBI time series simultaneously recorded using PPG wristbands and the ECG system. The occurrence frequency of basic patterns and their rankings were analyzed to calculate the IBS distance from gold-standard IBI, and to further calculate the signal-to-noise ratio (SNR) of the wristband IBI time series. Main results. The accuracies of both HRV and mental state classification were not satisfactory due to the low SNR in the wristband IBI. However, by rejecting data segments of SNR < 25, the Pearson correlation coefficients between the wristbands' HRV and the gold-standard HRV were increased from 0.542 ± 0.235 to 0.922 ± 0.120 for E4 and from 0.596 ± 0.227 to 0.859 ± 0.145 for Honor 5. The average accuracy of four-class mental state classification increased from 77.3% to 81.9% for E4 and from 79.3% to 83.3% for Honor 5. Significance. Consumer-grade PPG wristbands are acceptable for HR and HRV monitoring when removing low SNR segments. The proposed method can be applied for quantifying the accuracies of IBI and HRV indices acquired via any non-ECG system.

Funder

National Natural Science Foundation of China

Research and Development Program of China

Publisher

IOP Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3