A portable fan-based device for evaluating lung function in horses by the forced oscillation technique

Author:

Bizzotto DavideORCID,Paganini StefanoORCID,Stucchi LucaORCID,Avallone Matteo PalmisanoORCID,Ramirez Esther MillaresORCID,Pompilio Pasquale PORCID,Ferrucci FrancescoORCID,Lavoie Jean-PierreORCID,Dellacà Raffaele LORCID

Abstract

Abstract Objective. The assessment of lung mechanics in horses is nowadays based on invasive methods that may require sedation. The forced oscillation technique (FOT) allows the non-invasive assessment of respiratory mechanics during spontaneous breathing, but current devices are complex, cumbersome, expensive, and difficult to be applied in horses. Approach. We developed a portable FOT device based on a novel approach in which the pressure waveforms are generated by a servo-controlled ducted fan. This new approach allows the design of devices that are more sturdy, compact, and portable compared to already existing approaches. The prototype includes 1) a small microcontroller-based electronic board for controlling the fan and measuring flow and pressure and 2) an optimized data processing algorithm. Main results. This device provides a maximum error of 0.06 cmH2O·s/L and 0.15 cmH2O·s/L in measuring respiratory resistance and reactance during in-vitro validation. A pilot study was also performed on three healthy horses and three horses with severe equine asthma (SEA) and it demonstrated good tolerability and feasibility of the new device. Total respiratory system resistance (R rs) and reactance (X rs) significantly differed (p < 0.05) between groups. At 5 Hz, R rs was 0.66 ± 0.02 cmH2O·s/L and 0.94 ± 0.07 cmH2O·s/L in healthy and in SEA, respectively. X rs 0.38 ± 0.02 cmH2O·s/L and −0.27 ± 0.05 cmH2O·s/L. Significance. This novel approach for applying FOT allowed the development of a small, affordable, and portable device for the non-invasive evaluation of respiratory mechanics in spontaneously breathing horses, providing a useful new tool for improving veterinary respiratory medicine. Moreover, our results provide supporting evidence of the value of this novel approach for developing portable FOT devices also for applications in humans.

Funder

This work was partially supported by an unrestricted grant from Boehringer Ingelheim Animal Health Italia S.p.A.

Publisher

IOP Publishing

Subject

Physiology (medical),Biomedical Engineering,Physiology,Biophysics

Reference44 articles.

1. Comparative evaluation of devices used for measurement of respiratory input impedance in different centres;Brusasco;Eur. Respir. Rev.,1994

2. Technical and physiological determinants of airway smooth muscle mass in endobronchial biopsy samples of asthmatic horses;Bullone;J. Appl. Physiol.,2014

3. Development of a semiquantitative histological score for the diagnosis of heaves using endobronchial biopsy specimens in horses;Bullone;J. Vet. Intern. Med.,2016

4. Inflammatory airway disease of horses-revised consensus statement;Couëtil;J. Vet. Intern. Med.,2016

5. Blood gas, plasma lactate and bronchoalveolar lavage cytology analyses in racehorses with respiratory disease.;Couëtil;Equine Vet. J. Suppl.,1999

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3