Comparison of different modulations of photoplethysmography in extracting respiratory rate: from a physiological perspective

Author:

Liu HaipengORCID,Chen FeiORCID,Hartmann Vera,Khalid Syed Ghufran,Hughes Stephen,Zheng Dingchang

Abstract

Abstract Objective: Based on different physiological mechanisms, the respiratory modulations of photoplethysmography (PPG) signals differ in strength and resultant accuracy of respiratory frequency (RF) estimations. We aimed to investigate the strength of different respiratory modulations and the accuracy of resultant RF estimations in different body sites and two breathing patterns. Approach: PPG and reference respiratory signals were simultaneously measured over 60 s from 36 healthy subjects in six sites (arm, earlobe, finger, forehead, wrist-under (volar side), wrist-upper (dorsal side)). Respiratory signals were extracted from PPG recordings using four demodulation approaches: amplitude modulation (AM), baseline wandering (BW), frequency modulation (FM) and filtering. RFs were calculated from the PPG-derived and reference respiratory signals. To investigate the strength of respiratory modulations, the energy proportion in the range that covers 75% of the total energy in the reference respiratory signal, with RF in the middle, was calculated and compared between different modulations. Analysis of variance and the Scheirer–Ray–Hare test were performed with post hoc analysis. Main results: In normal breathing, FM was the only modulation whose RF was not significantly different from the reference RF (p > 0.05). Compared with other modulations, FM was significantly higher in energy proportion (p < 0.05) and lower in RF estimation error (p < 0.05). As to energy proportion, measurements from the finger and the forehead were not significantly different (p > 0.05), but both were significantly different from the other four sites (p < 0.05). In deep breathing, the RFs derived by BW, filtering and FM were not significantly different from the reference RF (p > 0.05). The RF estimation error of FM was significantly less than that of AM or BW (p < 0.05). The energy proportion of FM was significantly higher than that of other modulations (p < 0.05). Significance: Of all the respiratory modulations, FM has the highest strength and is appropriate for accurate RF estimation from PPG signals recorded at different sites and for different breathing patterns.

Funder

National Natural Science Foundation of China

Publisher

IOP Publishing

Subject

Physiology (medical),Biomedical Engineering,Physiology,Biophysics

Reference34 articles.

Cited by 35 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3