The effects of manual XCT focusing on extracted surface texture data

Author:

Slocombe JonathanORCID,Blunt LiamORCID

Abstract

Abstract X-Ray computed tomography, (XCT) has begun to prove itself as a valid method to quantify internal and external surface metrology of parts. However, the understanding of how a small change in the capture settings of the XCT can affect the surface data extracted from parts needs to be developed so that like all metrology instruments the operating window in which the technology provides repeatable results with minimum uncertainty is understood. For XCT there exists a clear point of uncertainty in the measurement process, this being at the generation point of the x-rays, at this point the electron beam impacts a target material causing the generation of x-rays. As the intensity and size of the electron beam focal spot have direct control of the produced x-rays, it is important to align the filament in such a way that the best quality radiographs are generated. The more optimally focused each individually radiograph is in an XCT scan the better quality the 3D model acquired will be, thus leading to more representative surface data extraction. The present paper details an investigation into the effects of this focusing procedure on the extracted surface data. Further to this, the results of the study were compared to work showing the variation in extracted surface data resulting from a full filament change. The present study found that variance in extracted surface texture parameters resulting from beam refocussing exceeded that when comparing filaments, leading to the conclusion that the installation process is likely to be the main contributing factor to the variance noted in both studies.

Publisher

IOP Publishing

Subject

Materials Chemistry,Surfaces, Coatings and Films,Process Chemistry and Technology,Instrumentation

Reference18 articles.

1. The Richardson constant for thermionic emission in Schottky barrier diodes;Crowell;Solid-State Electron.,1965

2. An investigation of the factors associated with the x-ray tube and their influence on dimensional measurement in micro-focus cane-beam industrial x-ray computed tomography systems;Flay,2016

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3