Abstract In this paper we show how a proper dimensioning of a magnetron cavity and its inner bulb allows one to design a hydrogen maser atomic clock with an arbitrary low frequency-temperature coefficient (FTC) for its cavity. The control of this parameter is of primary importance for the overall stability of the atomic clock. To this aim, a model based on finite element method has been developed to simulate thermal expansion of hydrogen maser cavities and evaluate the FTC. The model has been confronted with direct experimental data and very good agreement is observed. A key geometrical parameter is identified that allows for a strong tuning of the FTC, so as to set it down to values a priori as close as desired to 0, with limitations only dictated by the machining tolerances of the mechanical elements of the hydrogen maser cavity.

Funder

Belgian Walloon Region

Publisher

IOP Publishing

Subject

General Engineering

Reference15 articles.

1. Atomic hydrogen maser;Goldenberg;Phys. Rev. Lett.,1960

2. Theory of the hydrogen maser;Kleppner;Phys. Rev.,1962

3. Hydrogen-maser principles and techniques;Kleppner;Phys. Rev. A,1965

4. A review of contemporary atomic frequency standards;Schmittberger,2020

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Bimetal Temperature-Compensated Ramsey Cavity for Atomic Fountain Frequency Standards;IEEE Transactions on Microwave Theory and Techniques;2023-04

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3