Development and evaluation of a standard for absorbed dose to water from alpha-particle-emitting radionuclides

Author:

Khan Ahtesham UllahORCID,Radtke Jeff,Palmer Benjamin,Hull Jennifer,Kunugi Keith,DeWerd Larry

Abstract

Abstract Targeted radionuclide therapy and brachytherapy with alpha particles has gained significant clinical relevance recently. Absorbed dose traceability to a standard is currently lacking in the dosimetry chain. The short range of alpha particles in water of <100 μm complicates the absorbed dose measurements in the form of significant attenuation and perturbation effects. The aim of this work was to develop and validate a standard for absorbed dose to water from alpha-particle-emitting radionuclides. A dosimetric formalism to realize surface absorbed dose to water per unit activity using a windowless cylindrical parallel-plate ion chamber (IC) was introduced. IC-based and Monte Carlo (MC)-based correction factors were calculated for a planar circular 210Po alpha-particle emitter. The measured absorbed dose to air was compared to the MC-calculated absorbed dose. A parallel-plate IC with a nominal 4 mm collector diameter composed of polystyrene-equivalent material was utilized as a standard. MC simulations were performed using the TOPAS MC code and finite source size, backscatter, and emission angle divergence correction factors were calculated by modeling the IC and the source. Multiple measurement trials were performed to measure ionization current at air gaps in the 0.3 mm to 0.525 mm range. The proposed dosimetric formalism was employed to calculate the surface absorbed dose to water from a point-like 210Po source. The recombination and polarity correction factors were measured to be <0.50% when a 150 V mm−1 electric field strength was applied. The MC-calculated and measured absorbed dose to air agreed within 2.05%. The finite source size and backscatter corrections were <10% with the emission angle divergence correction being in the 93%–239% range. The surface absorbed dose to water was measured to be 2.8913 × 10−6 Gy s−1 Bq−1 with a combined uncertainty of 4.23% at k = 1. This work demonstrated the ability of a windowless parallel-plate IC as a standard for absorbed dose from alpha-particle-emitting radionuclides.

Publisher

IOP Publishing

Subject

General Engineering

Reference30 articles.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3