Abstract
Abstract
Langmuir probe diagnostic in a multi-dipole confined hot cathode discharge has been revisited with an improved sheath expansion model with fitted expansion parameters. The results show a three-temperature Maxwellian EEDF composition also observed in previous studies using a very similar system. The dependence on neutral pressure and discharge current of each electron species are consistent with known physical processes in a multi-dipole confined hot cathode discharge. This shows that the employment of the new ion saturation fitting method does not eliminate the contribution of the high energy degraded primaries to the Langmuir probe I–V trace, as sheath expansion and high energy electron current contributes differently on an I–V trace. The result remains supportive to the existence of a very hot (T
dp > 15 eV) degraded primary electron species separate from the typical hot electron (T
hot ∼ 3 eV) species. Thus it is recommended to sweep the Langmuir probe beyond the bias voltage of the hot cathode, whenever possible, in order to properly resolve the contribution to the I–V trace of the degraded primaries.
Funder
National Natural Science Foundation of China
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献