Abstract
Abstract
In this work we present a procedure for manufacturing an electrical device in the form of a quadrupolar electrical capacitor (QEC). The device is based on cotton fiber fabrics with carbonyl iron (CI) microparticles and self-adhesive copper foil, and surgical tape in the form of polyacrylic fiber fabrics, as element of consolidation and electrical insulation. By using an RLC electrical bridge, the equivalent electrical capacitance (C) and resistance (R) at the two gates of the QEC are measured as a function of magnetic flux density B. It is shown that both C and R have different values at the two gates and are sensitively influenced by the magnetic field. When
0
⩽
B
(
mT
)
⩽
100
, the electrical response function at the two gates has a resistive character due to magnetostriction of CI microparticles in the QEC body. For fixed voltages at one of the gates, B-dependent voltages are measured at the other gate. The structure at the two gates are quantified in terms of fractal parameters obtained from scanning electron microscopy images. The obtained characteristics shows that the obtained QEC can be used as a magnetic controllable resistor or as a magnetic field sensor for patients wearing pacemakers.
Funder
Romanian Plenipotentiary Representative at JINR
Subject
Electrical and Electronic Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science,Atomic and Molecular Physics, and Optics,Civil and Structural Engineering,Signal Processing